9MA10011
19/52
4.4.5 Print config.
4.4.5 ONBOARD CONFIGURATION
Do you want to print ?
^=Yes v=No
From this menu you can print the configuration of onboard inputs (see Printer
section).
4.5 Network 1
N.B.: This menu is for use by authorized personnel only. in fact, the network of
compatible Televis devices connected via RS485 to Memory 1000 can be modified
from this menu.
4.5
NETWORK 1
4.5.0
Network Mode
4.5.1
Self-configuration
4.5.2
-----------------------
4.5.3
-----------------------
4.5.4
General Info *
4.5.5
units
4.5.6
Print config. *
Menu available in models with RS485 only.
This menu allows you to configure ‘Network 1’ or the network of compatible Eliwell
Televis devices connected via serial port RS485 to Memory 1000.
4.5.0 Network Mode
4.5.0
NETWORK 1 MODE
Change data
Delete
Network configuration
Network type:
Televis
Network address
14:14
Max. units
15
Values modifiable only if REC= Off
•
Network type
: can be
Disabled
or
Televis
•
Network address
: set network address (MASTER Televis)
4.5.1 Self-configuration
4.5.1
SELF-CONFIGURATION
Change data
Delete
Network configuration
Network type:
Televis
Last
Address
0:1
First
Address
0:1
Automatic procedure to recognize compatible Eliwell Televis devices connected via
the RS485 serial port to Memory 1000. The procedure may take a few minutes to
self-configure depending on the number of devices in the network.
•
Last address
: set the value for the first address assigned to devices in the network.