FURTHER INFORMATION
Input/Output Characteristics
See ‘Connections’ section
Mechanical Characteristics
Casing:
PC+ABS UL94 V-0 resin casing, polycarbonate window, thermoplastic resin keys
Dimensions:
front panel 74x32 mm, depth 59 mm (without terminals)
Terminals:
screw/disconnectable terminals for cables with a diameter of 2,5mm
2
Connectors:
TTL for connection of Unicard/Copy Card
Humidity:
Operating / Storage: 10…90 % RH (non-condensing)
Regulations
Electromagnetic compatibility: The device conforms to Directive 2004/108/EC
Safety:
The device conforms to Directive 2006/95/EC
Food Safety:
The device complies with standard EN13485 as follows:
• suitable for storage
• application: air
• climate range A
• measurement class 1 in the range from -25°C to 15°C (*)
(* exclusively using Eliwell probes)
NOTE
: The technical specifications given in this document regarding measurement (range, accuracy, resolution, etc.) refer
to the instrument and not to any accessories provided, such as the probes. This means, for example, that the error introduced