Standard type 5 x 20 mm, 16 AT (tempered). Before exchanging a blown fuse, switch off the unit and
remove mains cable. Depress and turn the fuse holder anti-clockwise 1/8th and remove it.
If the new fuse blows immediately upon reconnection return the pack to an ELINCHROM service
centre for a check-up. (N.B. Check correct value of the fuse : 16 AT).
The button lights up when the pack is switched on. Switch off before removing the mains cord.
Note : the absence of charge, despite the switch being illuminated, indicates a fault.
While the MAINS SWITCH (4) is switched off firmly push in the plug of the
original ELINCHROM mains cord into the socket (1).
Select the required charging speed with the selector (3).
FAST :
is the standard position
recycling, for use in the professional studio.
(Position for the digital "one shot")
230 V = 16 A
115 V = 25 A
NORMAL :
standard recycling recommended for use in the studio with line 16 A.
(Position for the digital "multi-shot")
230 V = 12 A
115 V = 20 A
SLOW :
position is recommended when the mains capacity is too limited for the use with
the standard charge. (for the digital "multi-shot")
230 V = 8 A
115 V = 15 A
charge
N.B. SECURITY FUSE
This unit is protected by an internal security device. Should the unit not work properly, for example
because of a defective power component, the internal security fuse of 16AF (fast) would instantly get
destroyed, which avoids any recharging. From then on, the power pack requires a check up by a
technical Elinchrom service.
1. MAINS SUPPLY
2. FUSE
3. MAINS SWITCH
4. CHARGE SPEED SELECTOR