background image

11

The modelling lamp will only function when the lamphead is switched on (note : there is an
overheating control switch ON/OFF in the lamphead).

-

 Simple ON/OFF with ON setting indicated. Also incorporated is a slow start system to

   prolong lamp life

-

 Half power lamp setting further extends lamp life

-

 Adjusts the lamp to vary with the flash power.

DIM/BRIGHT CHARGE INDICATOR This setting underpowers the modelling lamps during

  charging. At full charge they <<indicate>> by coming to full brightness.

Used together, the modelling lamp extinguishes during charge.

This will display a channel number 0 - 8. keept this button pressed and when you have reached your
chosen number release. This sets the unit to the channel number displayed.
You can either select a different number for every head. If you wish to control two or more heads
identically then give them the same channel number, they will then respond to the same signal.

15. USE OF IRS

14. MODELLING LAMP CONTROLS

To activate the Infra Red System press the IRS Control

To use the IR-remote : 

first select a numbered channel on the handset.

This will activate the unit(s) allocated to that channel. No other units will respond. To measure the
f-stop, this unit can be flashed alone OR, to take an overall reading, ALL units will respond if «O»
is pressed on the handset.

If any other number is selected on the IR-handset, the IRS indicator will blink to advise
that the generator is not accepting the commands

.

IR Remote contr ol
code : 19319

Allocate the unit a channel number. First press the channel selector

Summary of Contents for digital 1500 AS

Page 1: ...TY STABILITY STABILITY STABILITY UNIVERSALITY UNIVERSALITY UNIVERSALITY UNIVERSALITY UNIVERSALITY TOTAL TOTAL TOTAL TOTAL TOTAL ASYMMETRY ASYMMETRY ASYMMETRY ASYMMETRY ASYMMETRY For DIGITAL PHOTOGRAPH...

Page 2: ...8 8 8 8 Power variator 9 9 9 9 9 Troubleshooting 9 9 9 9 9 Photo cell 10 10 10 10 10 Synchronization 10 10 10 10 10 Audible signal 10 10 10 10 10 Modelling lamp selector 11 11 11 11 11 IRS remote con...

Page 3: ...to the ventilation holes The units may retain an internal charge for a considerable time even though disconnected from the power supply Thank you for buying your Digital 1500 AS flash generator All El...

Page 4: ...ector IR 1 8 packs 12 Multi purpose accoustic signal 13 Half full power for modelling lamps 14 Modelling lamps on off 15 Modelling lamp dimmer charge signal 16 Proportional modelling light 17 Power ou...

Page 5: ...illuminated 6 Select charging rate 3 normal 7 Select modelling lamp setting 16 8 Connect the synchro cord on the socket 7 9 Check that photocell 6 is OFF not illuminated 10 Switch on the lampheads the...

Page 6: ...x 27 cms Weight 8 6 kg TECHNICAL DATA RELATION OF POWER RANGE BETWEEN THE OUTLETS Guide aperture is based on the Digital S head and the standard reflector distance 1 m 3 3 ft and film ISO 100 21 DIN T...

Page 7: ...harging speed with the selector 3 FAST is the standard position recycling for use in the professional studio Position for the digital one shot 230 V 16 A 115 V 25 A NORMAL standard recycling recommend...

Page 8: ...ve is the only time when the open flash will function while the indicator blinks At other times the generator is not ready still charging or fed with incorrect requests and will therefore not function...

Page 9: ...gressively with the principal power read out The limite are only the maximum power of the pack and the minimum power through one outlet all steps being in 1 10th f stops If the power display blinks th...

Page 10: ...transmitter code 19306 which releases the flash instantaneously faster but slightly slower than by sync cable Therefore use 1 60th for focal plane shutters and 1 125th for in lens shutters In difficu...

Page 11: ...e This sets the unit to the channel number displayed You can either select a different number for every head If you wish to control two or more heads identically then give them the same channel number...

Page 12: ...F extends lamp and tube life If the power display does not illuminate i e ON OFF appears not to function the lamphead is incorrectly fitted the connector is damaged or it is an old lamphead unadapted...

Page 13: ...on it is probable that the flash tube may be shorter than our standard lampheads The X heads X6000N Twin X4 X8000 has two special flash tubes that focus and maximise the light ouput FOR YOUR SAFETY US...

Page 14: ...Below is a table listing lampheads made since 1980 which are adaptable and indicates the equivalent in the current series 1500 2400 WS S1500 N S2000 S2 S Mini 1500 A2000 A2 2400 Ws 2000 Mini A R 2000...

Page 15: ...aster 105 385 cm 30149B Spots Spots Spots Spots Spots code code code code code Zoom 12 24 26471 Mini spot 26420 fresnel spot 26450 Bags Bags Bags Bags Bags code code code code code Carrying bag for 3...

Page 16: ...16 Visit our Web site www elinchrom com Elinca s a E Digital 1500 AS 73315 Printed in Switzerland...

Reviews: