9
• If not already done, install 1/2” conduit connector in j-
box.
Run 3 wires; black, white and green ,according to the
National Electrical Code and local codes and
ordinances, in 1/2" conduit from service panel to
junction box.
Connect black wire from service panel to black or red in
junction box, white to white and green to green-yellow.
Close and secure junction box cover.
• Install the grease filters supporting frame:
e.
Install the grease filter and turn power on at service panel.
Check operation of the hood.
If range hood does not operate:
• Check that the circuit breaker is not tripped or the house
fuse blown.
• Disconnect power supply. Check that wiring is correct.
To get the most efficient use from your new range hood,
read the “Use and Care Information” section.
Keep your Installation Instructions and Use and Care
Guide close to range hood for easy reference.
a.
Open perimetral plate
c.
Position the frame in the casing of the hood.
b.
Remove installed filters.
d.
Secure it to the hood with 6 screws.
IMPORTANT: Remove the light bulbs before installing
the supporting frame. Refer to the maintenance section
for instructions.
e.
Re- install the light bulbs.