![ELGi TRC 1000 MN UG Owner'S Manual Download Page 19](http://html1.mh-extra.com/html/elgi/trc-1000-mn-ug/trc-1000-mn-ug_owners-manual_2388595019.webp)
19
Disc coupling model assy instructions
CORRECTIVE ACTION
a. It’s required to rotate the motor towards left by keeping the bolt no ‘1’
fixed, loosing bolt no 2,3&4 and by pushing the side screw at bolt
number 4.
b. Shift motor by side screws towers left by keeping a close watch on dial
gauge reading till dial gauge reading.
c. After above activities, tighten the motor foundation bolts fully, and agian
take dial gauge reading for angular.
d. The allowable limit for radial is 1.7mm at
Ø
300 (TIR) as such please
follow above procedure till the reading are within limits.
e. Once axial /angular/radial readings are brought within tolerances (i.e.,
25% of the tolerance mentioned on the coupling drawing) fix all the
foundation bolt and tighten all coupling bolts to the required
torque (33 N-m).
Hub motor side
Disc pack
Spacer
Disc pack
Hub compressor side
Hex nut
Hex bolt
Over load washer
Summary of Contents for TRC 1000 MN UG
Page 8: ...8 General view of the compressor...
Page 37: ...37 Spare parts list...
Page 38: ...38 Fig 1 Package assy TRC 1000 MN UG TPL No S 07096...
Page 40: ...40 Fig 2 Unit assy TRC 1000 MN UG...
Page 42: ...42 Fig 2 Unit assy TRC 1000 MN UG...
Page 44: ...44 Fig 3 Cooling System...
Page 46: ...46 Fig 3 Motor fan assy...
Page 50: ...50 Fig 6 Air filter assembly Part No 070309310 1 2 5 4 3...
Page 52: ...52 Fig 8 Breather valve assy Fig 6 Drain valve assy 1 4 BSP...
Page 56: ...56 Notes...
Page 57: ...57 Notes...
Page 58: ...58 Notes...
Page 59: ...59 Notes...
Page 63: ......
Page 64: ...64...
Page 76: ...76...
Page 77: ...77...
Page 78: ...78...
Page 79: ...79...
Page 81: ...81...