Elgar CW-M Series
2.7 General
Dimensions
CW 801M: 3.5" H (89 mm) x 19" W (483 mm) x 20.6" D (524 mm)
CW 1251M: 3.5" H (89 mm) x 19" W (483 mm) x 20.6" D (524 mm)
CW 2501M: 5.25" H (133 mm) x 19" W (483 mm) x 20.6" D (524 mm)
Weight
CW 801M: 48 lbs. (22 kg)
CW 1251M: 53 lbs. (24 kg)
CW 2501M: 86 lbs. (39 kg)
Shipping Weight
CW 801M: 56 lbs. (25 kg)
CW 1251M: 61 lbs. (28 kg)
CW 2501M: 94 lbs. (43 kg)
Regulatory Compliance
CE mark
LVD: EN61010-1:1993 + Amendment 2
EMC: EN55011:1991 Group 1, Class A, EN50082-1:1992
Environmental
Cooling: Dual fan speed with side air intake, exhaust to rear
Operating Temperature: 0 to 40°C
Storage Temperature: -40 to +70°C
Humidity: 0 to 85% at 25°C derate to 50% above 40°C (non-condensing)
Altitude: Operating full power available up to 6,000 feet, non-operating to 40,000 feet
Installation Category III, Pollution Degree 2
FOR INDOOR USE ONLY
7
Summary of Contents for CW 1251M
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ...ii This page intentionally left blank...
Page 12: ...Elgar CW M Series This page intentionally left blank 2...
Page 24: ...Elgar CW M Series Figure 3 2 Mounting Dimensions Front and Rear Views CW 801M CW 1251M 14...
Page 25: ...Elgar CW M Series Figure 3 3 Mounting Dimensions Front and Rear Views CW 2501M 15...
Page 26: ...Elgar CW M Series Figure 3 4 Mounting Dimensions Top and Side Views CW 801M CW 1251M 16...
Page 27: ...Elgar CW M Series Figure 3 5 Mounting Dimensions Top and Side Views CW 2501M 17...
Page 34: ...Elgar CW M Series This page intentionally left blank 24...
Page 38: ...Elgar CW M Series 4 3 2 Setup for Six in Parallel Configuration 28...
Page 39: ...Elgar CW M Series 4 3 3 Setup for Six Phase Configuration 29...
Page 40: ...Elgar CW M Series 4 3 4 Setup for Two Phase Configuration 30...
Page 42: ...Elgar CW M Series This page intentionally left blank 32...
Page 48: ...Elgar CW M Series This page intentionally left blank 38...