Manual operating of flash lamps FX PRO serie
www.elfo.com.pl
Page 11
X.
Protections
All lamps FX PRO serie are doubly fused:
main fuse – time delay fuse T4/4A in FX 600 PRO and T6.3/6.3 A in FX 1200 PRO;
modelling light bulb fuse - fast F2/2A in FX 600 PRO and F4/4A in FX 1200 PRO;
thermal fuse on/off automatic.
Main power circuits of the lamp and capacitors are protected against overheating. The
lamp can be turned off automatically when temperature exceeds critical values. It may occur
when lamp works intensively (frequent flash with modelling light, and small accessories), or
there is high outer temperature. If it occurs, symbol
oF
appears on display, and steady sound
is audible. Then lamp has to be off, and it is required to assure suitable air circulation, and
wait until lamp is on automatically. It may take several minutes dependently on overheating
degree.
XI.
Service
In the case of lamp failure or in the event that the correctness of your lamp aroused
concerns, please contact us by phone or e-mail:
ELFO
®
Jan Tulikowski
ul. Zgierska 231D
91-495 Łódź
POLAND
tel.: +48 42 658 26 01
+48 42 658 83 44
fax: +48 42 658 81 56
e-mail: [email protected]
www: www.elfo.com.pl
Opening hours: 8
00
- 16
00
(from Monday to Friday).