background image

Page 9

Guardian Bridge Advanced User Manual

Button Behavior

BY ELEXA

LED

Behavior

This happens when…

First LED (Z-Wave)

1st LED Blinking in 500ms Guardian Bridge isn’t in a Z-Wave Network

1st LED Turned Off

Guardian Bridge is included in a Z-Wave 

Network

1st LED Flash

1st LED will flash every time that a 

Z-Wave transmission happens.

Second LED 

(Power)

LED is On

Guardian Bridge is Powered On

Third LED 

(Guardian RF)

LED Flashes

3rd LED will flash every time that a 

Guardian RF transmission happens.

Action

Condition

Result

Push Button 

3x within 1,5 

seconds

Always

Guardian Bridge will enter in Learn Mode  

(Add/Remove from a Z-Wave Network)  

Press and Hold 

for 10 seconds

Always

The Guardian Bridge memory will be erased to 

factory settings  excluding all Associations. This 

procedure also sends a Device Reset Locally to 

AG01 - Lifeline notification.

 
 

Association Groups (AGs)

The Guardian Bridge supports up to 5 Node IDs on AGs. Please see be-
low a description of all available Association Groups:

Association Group 01

Lifeline

This AG sends Binary Report when happens a Valve 

Open/Close action.

It also supports a Device Reset Locally.

When any Guardian Leak Detector is wet, the Device 

will send a Leak Notification

Association Group 02

This AG supports a Open/Close Basic Report

Association Group 03

This AG supports a Sensor Multilevel Report contain-

ing the Temperature information every 60 seconds

Button Behavior

Summary of Contents for GUARDIAN GBR1

Page 1: ...GBR1 User Manual Guardian Bridge BY ELEXA ...

Page 2: ...eginner user please visit www getguardian com for instructions This manual will pro vide in depth technical information about the Guardian Bridge especially in regards to its compliance to the Z Wave standard such as compatible Command Classes Association Group capabilities special features and other information that will help you maximize the utility of this product in your system Preface ...

Page 3: ...ble of Contents Preface 2 Description 4 Specifications 4 Inclusion Exclusion 5 Reset to Factory Default 6 Physical Installation 7 LEDs Behavior 8 Button Behavior 9 Compatible Command Classes 10 Configuration Command Class Parameters 12 Troubleshooting 13 Warranty Support 14 ...

Page 4: ...pply 5 VDC OR 12VDC Working current NA Operating temperature 0 40 C Radio frequency 908 4 MHz US Z Wave 915 MHz LoRa Range Up to 40m Z Wave depending on environment Up to 500m LoRa Dimensions L x W Board 119 x 60 mm Update OTA Guardian Bridge device was developed to provide the Guardian product line compatibility with Z Wave Network protocol Description ...

Page 5: ...ton 3 times quickly within 1 5 seconds Upon successful exclusion the 1st LED will start blinking in 500ms NWI Network Wide Inclusion This Device supports NWI Network Wide Inclusion 1 Follow the instructions for your Z Wave controller to enter on Inclusion Exclu sion mode 2 Supply power to the Guardian Bridge to begin inclusion exclusion mode If the Guardian Bridge is already powered on NWI will be...

Page 6: ...eware that resetting your device will disconnect it from the system 1 Make sure that your Guardian Bridge is powered on 2 Press Hold the button for 10 seconds 3 The 1st LED will turn on and right after that release the Button The Guardian Bridge memory will be erased to factory settings excluding all Associations This procedure also sends a Device Reset Locally to AG01 Lifeline notification 4 The ...

Page 7: ...stallationBY ELEXA The Guardian Bridge can be plugged directly into a Micro USB power supply Include the Guardian Bridge into your Z Wave network and make sure it can communicate from the installation location before continuing further Physical Installation ...

Page 8: ...ridge isn t in a Z Wave Network 1st LED Turned Off Guardian Bridge is included in a Z Wave Network 1st LED Flash 1st LED will flash every time that a Z Wave transmission happens Second LED Power LED is On Guardian Bridge is Powered On Third LED Guardian RF LED Flashes 3rd LED will flash every time that a Guardian RF transmission happens LEDs Behavior ...

Page 9: ...G01 Lifeline notification Association Groups AGs The Guardian Bridge supports up to 5 Node IDs on AGs Please see be low a description of all available Association Groups Association Group 01 Lifeline This AG sends Binary Report when happens a Valve Open Close action It also supports a Device Reset Locally When any Guardian Leak Detector is wet the Device will send a Leak Notification Association G...

Page 10: ...sor Type 01 Temperature Precision Scale Size Celsius 01 Precision 000 Scale 00 Size 001 Precision Scale Size Farenheit 01 Precision 000 Scale 00 Size 001 Sensor Data 00 FF 125 125 in Degrees Fahrenheit or Celsius COMMAND_CLASS_MULTI_CHANNEL V4 60 The Multi Channel Command Class is used to distinguish commands to from the Valve Controller endpoint endpoint 1 and the Leak De tector endpoint endpoint...

Page 11: ...arm Type 00 Unsupported V1 Alarm Level 00 Unsupported Notification Status FF Unsolicited Reporting is Enabled Notification Type05 Water Alarm Leak Detected Event 02 Water Leak Detected Unknown Location Leak Removed Event 00 Event Inactive Sequence Reserved Event Parameters Length 00 Notification Event Parameters 00 No Event Parameters COMMAND_CLASS_ZWAVE_PLUS INFO V2 5E Returned Value 01 05 00 15 ...

Page 12: ...is as shown below Note that the value sent must be the exact size in bytes as accepted by the setting The extra spaces should be filled with zeros see the value column below Example Configuration Parameter 02 02 00 0A Param Size Value 02 Param 2 02 2 Bytes 00 0A 10 Configuration Command Class Parameters Size Name Available Values Default Value 01 This parameter sets the Temperature scale Is possib...

Page 13: ...Page 13 Guardian Bridge Advanced User Manual Troubleshooting BY ELEXA A A Under Development Troubleshooting ...

Page 14: ... normal use in the United States or Canada To obtain warranty service during the Warranty Period call Elexa Customer Service 1 855 249 1754 or email support getguardian com for instructions on sending damaged parts and documentation for a Return Material Authorization RMA Products returned to ECP for repair or replacement without authorization will be returned at the sender s expense All warranty ...

Reviews: