Page 5
Guardian Bridge Advanced User Manual
Inclusion & Exclusion
BY ELEXA
Inclusion (Add to System) for Z-Wave and LoRa
1. For proper inclusion, bring the Guardian Bridge to the final location where it will
be used*.
2. Follow the instructions for your Z-Wave controller to enter on inclusion mode.
3. Supply power to the Guardian Bridge to begin inclusion mode. If the Guard-
ian Bridge is already powered on, press the button 3 times quickly within 1,5 se-
conds.
4. The device will enter inclusion mode for 15 seconds.
Upon successful inclusion, the 1st LED will stop blinking and stay turned off.
Exclusion (Remove from System) for Z-Wave and LoRa
Follow the instructions for your Z-Wave Certified Controller to enter exclusion
mode. When prompted by the controller:
1. Make sure the Guardian Bridge is powered on.
2. Press the Button 3 times quickly within 1,5 seconds.
Upon successful exclusion, the 1st LED will start blinking in 500ms.
NWI - Network Wide Inclusion
This Device supports NWI - Network Wide Inclusion.
1. Follow the instructions for your Z-Wave controller to enter on Inclusion/Exclu-
sion mode.
2. Supply power to the Guardian Bridge to begin inclusion/exclusion mode. If
the Guardian Bridge is already powered on, NWI will be activated automatically if
Guardian Bridge is already out of a Z-Wave Network.
3. When Guardian Bridge is out a Z-Wave Network, and Controller enters in Exclu-
sion mode, Guardian Bridge will be removed automatically through the NWI.
Upon successful in both cases, results is the same as Inclusion/Exclusion Default
procedures.
*For non Z-Wave Plus networks, please consult the owner’s manual for your primary controller to determine the best method/location
for adding the Guardian Bridge to your Z-Wave network. A Security Enabled Z-Wave Controller must be used in order to fully utilize the
product.
Inclusion & Exclusion