40
USER MANUAL TPS/M/D 62000447 REV 00_
–
31/08/2021
5.
TABLE OF THE DATA SAVED ON THE USB
Item
Name
Description
1
Standby/Ready/Failure
0= Standby, 1= Ready, 2= Failure,
2
Output
0=OFF, 1=ON
3
Output mode DC
0 = AC, 1= DC
4
Output mode mono-phase
0 = 1PH, 1= 3PH
5
4-wire sense
0 = 2 wire 1 = 4 wire
6
Voltage setpoint L1
Set voltage of L1 [V]
7
Voltage setpoint L2
Set voltage of L2 [V]
8
Voltage setpoint L3
Set voltage of L3 [V]
9
Voltage setpoint ALL
Set voltage of all the phase together [V]
10
Frequency setpoint
Set frequency for all the phases [Hz]
11
Phase setpoint L1
Set phase of L1[deg]
12
Phase setpoint L2
Set phase of L2[deg]
13
Phase setpoint L3
Set phase of L3[deg]
14
Voltage output L1
Measured output voltage of L1 [V]
15
Voltage output L2
Measured output voltage of L2 [V]
16
Voltage output L3
Measured output voltage of L3 [V]
17
Current output L1
Measured output current of L1 [A]
18
Current output L2
Measured output current of L2 [A]
19
Current output L3
Measured output current of L3 [A]
20
Fail L1
0 = no blocking alarm, 1= blocking alarm
21
Fail L2
0 = no blocking alarm, 1= blocking alarm
22
Fail L3
0 = no blocking alarm, 1= blocking alarm
23
Alarms L1
Alarm of the L1 line
24
Alarms L2
Alarm of the L2 line
25
Alarms L3
Alarm of the L3 line
26
Uptime [day]
The number of days from the turn on
27
Uptime [hour]
The number of hours from the turn on
28
Uptime [min]
The number of minutes from the turn on
29
Uptime [sec]
The number of seconds from the turn on
30
Running [day]
The number of days with the output active from the last
turn on of the machine
31
Running [hour]
The number of hours with the output active from the
last turn on of the machine
32
Running [min]
The number of minutes with the output active from
the last turn on of the machine
33
Running [sec]
The number of seconds with the output active from the
last turn on of the machine
Summary of Contents for TPS/M/D
Page 1: ...1 USER MANUAL TPS M 62000595 REV 03_ 01 06 2021 TPS M D USER MANUAL ...
Page 13: ...13 USER MANUAL TPS M 62000595 REV 03_ 01 06 2021 1 4 3 TPS M D 6KVA 281 513 ...
Page 14: ...14 USER MANUAL TPS M 62000595 REV 03_ 01 06 2021 1 4 4 TPS M D 9KVA 281 513 ...
Page 25: ...25 USER MANUAL TPS M D 62000447 REV 00_ 31 08 2021 2 3 2 4 WIRE CONFIGURATION TPS M D TPS M D ...
Page 36: ...36 USER MANUAL TPS M D 62000447 REV 00_ 31 08 2021 Limitations is enable both AC and DC mode ...