20
5.4 EVERY FOUR YEARS
Every four years the machine must undergo a complete technical and operational review. Such work
must be performed by the manufacturing firm or at the dealers location with skilled technical
personnel.
ATTENTION
The manufacturing firm is not liable for any damage caused by the machine due to lack of
review.
NOTE: The tank O.ring MUST be replaced every five (5) years according to the manufacture
specification.
5.5 PUTTING THE MACHINE OUT OF SERVICE
1) Empty the electrolyte and rinse the tank.
2) Empty the liquid deoxidizer from the Booster Tank.
3) Disassemble the machine components and store them separately, according to the material
they are made of.
5.6 SCRAPPING
Hand the materials that can be salvaged to companies specializing in recycling raw materials.
5.7 DISPOSING OF THE ELECTROLYTE
Neutralize it to PH7 by adding hydrochloric acid (and small part of albite in powder) and give material
to a company qualified and authorized in treating and disposing that handles toxic waste material.
5.8 DISPOSING DEOXIDIZER LIQUID
It can be regenerated by distillation. Alternatively, it must be handed over to a company specializing
in the disposal of toxic products.