When the torch trigger is pressed, the current begins to 
increase over the previously set "slope up" time (LED 

N

 lit), 

until it reaches the value set by means of the knob 

Q

. The 

LED 

O

 lights and appears on the display 

S

Should it be necessary to reduce the current during welding, 
without shutting of the arc (for instance when changing the 
welding material or working position, moving from horizontal 
to upright, etc.…), press and immediately release the torch 
trigger: the current will switch to the second value selected, 
the LED 

A7

 will light and 

O

 will go off. 

To return to the previous main current, press and release the 
torch trigger once again. The LED 

O

 will light, and the LED 

A7

 will go off. To stop welding at any time, simply hold down 

the torch trigger for more than 0.7 seconds, then release. 
The current begins to fall to zero within the previously set 
"slope down" time interval (LED 

A6

 lit). 

If you press and immediately release the torch trigger during 
the "slope down" phase, you will return to "slope up" if it is set 
to greater than zero, or to the lesser current value of those 
set. 
NOTE: The expression "PRESS AND IMMEDIATELY 
RELEASE" refers to a maximum time of 0.5 seconds. 
 

 LED W - 4-step TIG welding with three levels of 

current (automatic trilevel).

 

To set the three welding currents, proceed as follows: 
Press the selector switch 

H

 until the LED 

O

 lights, then adjust 

the maximum current value using the knob 

Q

Press the selector switch 

H

 until the LED 

A7

 lights, then 

adjust the intermediate current value using the knob 

Q

Press the selector switch 

H

 until the LED 

M

 lights, then adjust 

the starting current value using the knob 

Q

The operating logic is the same as previously described for 
welding with dual current level LED 

V

 

 LED A1 - 4-step TIG welding with special 

program 

 

To light the arc, press the torch trigger and hold it down; the 
current begins to increase at a fixed rate. If the torch trigger 
is released, the current immediately rises to the welding 
value (LED 

O

). To stop welding, press the torch trigger and 

hold it down; the current begins to drop at a fixed rate. The 
current immediately returns to zero if the trigger is released. 
 

 

LED A4 - Selector switch for high frequency 

ignition and pulsed arc mode, on-off 

This push-button selects the ignition type (with high 
frequency or by contact) and the continuous or pulsed arc 
mode. The selection changes each time the button is 
pressed. 
The LEDs light next to the various symbols to display your 
choice.

 

 

 

LED A2 - Ignition with high frequency or by 

contact. 

When the LED is off, to start the arc press the torch trigger 
and touch the tungsten electrode to the workpiece, then lift it. 
This move must be quick and sharp. 
When the LED is on, to start the arc, press the torch trigger: 
a high voltage/frequency pilot spark will start the arc. 
 

 

LED A3 - Pulsed arc, on-off 

When the LED is on, the pulsed arc mode is activated. 

From a pulse frequency of 0.16 to 1.1Hz, the 

display 

alternately shows the peak (main) current and the base 
current 
The 

and 

LEDs light alternately: beyond 1.1 Hz the 

display shows the mean of the two currents and the 

and 

LEDs both remain on. 
When the LED is off, the continuous mode is activated. 
 

 

H – MMA and TIG welding parameters selector 

switch 

Pressing this button will light the LEDs in sequence:  

Warning: only those LEDs which refer to the chosen 
welding mode will light;

 e.g. in continuous TIG welding the 

LED, representing the pulse frequency, will not light. 

Each LED indicates the parameter, which may be adjusted 
via the 

knob during the lighting time of the LED. 

5 seconds after the last variation, the LED involved will light 
off; the main welding current will then be displayed and the 
corresponding 

O

 LED will light. 

 

 

LED G 

Hot-Start LED. May be selected via the button 

H

 only if 

MMA welding is selected (LED 

A)

This LED lights to indicate that the display 

S

 displays the 

time, expressed in seconds, during which the welding 
machine delivers an overcurrent to improve electrode 
starting. It may be adjusted using the knob 

Q

 

 

LED I 

Arc-force LED. May be selected via the button 

H

 only if 

MMA welding is selected LED 

A

It is a percentage of the welding current. The display 

S

 

displays its value, and the knob 

Q

 adjusts it. This 

overcurrent essentially aids in the transfer of drops of molten 
metal. 

 

 LED L 

Pre-gas LED. Adjustment 0.05-2.5 seconds. Gas output 
time before starting welding. 
 

 LED M 

Welding start current LED. This is a percentage of the 
welding current LED 

O

 in three levels mode. 

 

LED N 

Slope up LED. This is the time in which the current, starting 
from the minimum, reaches the set current value. (0-10 sec.) 
 

Summary of Contents for TIG 118

Page 1: ...ge 20 E MANUAL DE INSTRUCCIONES PARA SOLDADORAS DE ARCO Pag 26 P MANUAL DE INSTRU ES PARA SOLDADORES A ARCO Pag 32 NL HANDLEIDING VOOR LASTOESTELLEN Pag 38 Parti di ricambio e schema elettrico Spare p...

Page 2: ...addizionale C significa che l apparecchio protetto contro l accesso di un utensile diametro 2 5 mm alle parti in tensione del circuito di alimentazione Idoneit ad ambienti con rischio accresciuto NOT...

Page 3: ...ventivamente regolato per ritornare a zero LED D Saldatura a TIG 4 tempi automatico Questo programma differisce dal precedente perch sia l accensione che lo spegnimento vengono comandati premendo e ri...

Page 4: ...nto fisso Se si rilascia il pulsante la corrente sale immediatamente al valore di saldatura LED O Per terminare la saldatura premere il pulsante torcia e mantenendolo premuto la corrente inizia a dimi...

Page 5: ...pulsante H e regolate con la manopola Q Nelle procedure di blocco vedi 2 3 2 della macchina visualizza tre punti lampeggianti o accesi di continuo le sigle E1 E2 E3 E4 la sigla H2O T Display Normalme...

Page 6: ...morsetto al pezzo nel punto pi vicino possibile alla saldatura assicurandosi che vi sia un buon contatto elettrico Collegare il connettore di potenza della torcia TIG al polo negativo della saldatrice...

Page 7: ...l procedimento e il modo di saldatura paragrafo 3 2 Girare la manopola Q ed impostare la corrente di saldatura Se stato scelto il procedimento TIG attivare il LED A5 post gas tramite il pulsante H e r...

Page 8: ...the live parts of the power circuit by a tool diameter 2 5 mm Suitable for hazardous environments NOTES the welding machine has also been designed for use in environments with a pollution rating of 3...

Page 9: ...started and extinguished by pressing and releasing the TIG torch trigger LED E TIG spot welding LED manual After selecting the welding current LED O and the spot welding time LED P using the selector...

Page 10: ...on and pulsed arc mode on off This push button selects the ignition type with high frequency or by contact and the continuous or pulsed arc mode The selection changes each time the button is pressed T...

Page 11: ...ormally displays the arc voltage in relation to the current welding process When setting the cooling unit operation it displays the status of this unit V U Selector switch for programs in memory Selec...

Page 12: ...e the machine is powered The first time the machine is turned on select the mode using the push buttons C Z and A4 and the welding parameters by means of the key H and the knob Q as described in parag...

Page 13: ...a saved program Beginning with a previously saved program the operator may edit the data in memory to update the program itself or to find new parameters to save in another program 3 6 3 1 Update Alte...

Page 14: ...C gibt an dass das Ger t gegen das Eindringen eines Werkzeugs Durchmesser 2 5 mm in den Bereich der aktiven Teile des Stromversorgungskreises gesch tzt ist Geeignet zum Betrieb in Umgebungen mit erh...

Page 15: ...llten Zeit slope down LED A6 leuchtet auf den Wert 0 D LED WIG Schwei en 4 Takt Automatikbetrieb Dieses Programm unterscheidet sich von dem vorherigen darin dass sowohl die Z ndung als auch das L sche...

Page 16: ...st man den Brennertaster sinkt der Strom augenblicklich auf Null A4 On Off Wahlschalter f r Hochfrequenzz ndung und Impulsschwei en Mit diesem Wahlschalter w hlt man das Z ndverfahren HF oder Ber hrun...

Page 17: ...gt den Schwei strom und die mit dem Wahltaster H gew hlten und mit Regler Q eingestellten Werte an Im Falle der Verriegelung der Maschine siehe 2 3 2 zeigt es Folgendes an Drei blinkende oder st ndig...

Page 18: ...ei en von rostfreiem Stahl Eisen und Kupfer mit dem WIG Verfahren geeignet Den Steckverbinder des Massekabels an den Pluspol der Schwei maschine und die Klemme an das Werkst ck m glichst nahe bei der...

Page 19: ...rfahren und die Betriebsart w hlen Abschnitt 3 2 Regler Q drehen und den Schwei strom einstellen Wenn das WIG Verfahren gew hlt wurde die LED A5 post gas mit Drucktaster H einschalten und mit dem Regl...

Page 20: ...tension du circuit d alimentation avec un outil diam tre 2 5 mm Indiqu pour tre utilis dans des milieux avec un risque accru NOTE De plus ce poste souder est indiqu pour tre utilis dans des milieux a...

Page 21: ...ir 0 Voyant D Soudure TIG 4 temps automatique Ce programme diff re du pr c dent parce que l allumage et l extinction sont command s en appuyant et en rel chant le bouton de la torche TIG Voyant E Soud...

Page 22: ...rant monte imm diatement jusqu la valeur de soudure voyant O Pour terminer la soudure appuyer sur le bouton de la torche et le garder enfonc le courant commence d cro tre Lorsqu on rel che le bouton l...

Page 23: ...fiche le courant de soudure et les d finitions s lectionn es l aide du bouton H et r gl es au moyen du bouton Q Dans les proc dures d arr t voir 2 3 2 de la machine affiche trois points clignotants ou...

Page 24: ...er inoxydable le fer et le cuivre avec le proc d TIG Raccorder le connecteur du c ble de masse au p le plus du poste souder et la borne la pi ce souder dans le point le plus pr s possible de la soudur...

Page 25: ...ment sur le bouton U et choisir le num ro de programme d sir Les programmes libres ont un symbole clignotant Appuyer sur les boutons C Z et A4 et choisir le proc d et le mode de soudure paragraphe 3 2...

Page 26: ...ifica que el equipo est protegido contra el acceso de una herramienta di metro 2 5 mm a las partes en tensi n del circuito de alimentaci n Idoneidad a ambientes con riesgo aumentado NOTE La soldadora...

Page 27: ...endido previamente ajustado para volver a cero Led D Soldadura TIG de 4 tiempos autom tico Este programa se diferencia del anterior porque tanto el encendido como el apagado vienen activados oprimiend...

Page 28: ...el pulsador de la antorcha y manteni ndolo presionado la corriente empieza a aumentar con un incremento fijo Si se soltase el pulsador la corriente subir a inmediatamente al valor de soldadura led O...

Page 29: ...factor de servicio o de intermitencia porcentual admitido por la m quina y simult neamente bloquea el suministro de corriente N B En esta condici n el ventilador sigue enfriando el generador S Display...

Page 30: ...ectrodo a la posici n de soldadura y al tipo de uni n por realizar Terminada la soldadura apagar siempre el aparato y quitar el electrodo de la pinza porta electrodo Si se quisieran regular las funcio...

Page 31: ...UNA MEMORIZACION 3 6 2 Memorizar de un programa libre El operador puede modificar y memorizar un programa elegido procediendo de la forma siguiente Presionar los pulsadores U en modo breve y elegir e...

Page 32: ...C a letra adicional C significa que o aparelho est protegido contra o acesso de um utens lio di metro 2 5 mm nas partes em tens o do circuito de alimenta o Idoneidade em ambientes com risco acrescenta...

Page 33: ...4 tempos autom tico Este programa distingui se do anterior porque tanto a opera o de ligar como a de desligar s o comandadas pressionando e soltando o bot o tocha TIG LED E Sinalizador por pun o Manu...

Page 34: ...do o carregado a corrente come a a aumentar com um incremento fixo Se o gatilho for solto a corrente sobe imediatamente para o valor de soldadura sinalizador O Para terminar a soldadura carregar no ga...

Page 35: ...rador S Display Visualiza a corrente de soldadura e as defini es seleccionadas com o bot o H e reguladas com o man pulo Q Nos procedimentos de bloqueio veja 2 3 2 a m quina visualiza Tr s pontos lampe...

Page 36: ...e o cobre Ligar o conector do cabo de massa ao p lo positivo da m quina de soldadura e o borne pe a no ponto mais pr ximo poss vel da m quina de soldadura certificando se que haja um bom contacto el...

Page 37: ...te Carregar nos bot os C Z e A4 e escolher o procedimento e o modo de soldagem par grafo 3 2 Girar o man pulo Q e estabelecer a corrente de soldagem Se for escolhido o procedimento TIG activar o sinal...

Page 38: ...u de delen van het stroomcircuit die onder spanning staan niet kunt aanraken met behulp van een sleutel diameter 2 5 mm Geschikt voor gevaarlijke omgevingen NOTES de lastoestellen zijn ook ontworpen...

Page 39: ...electieschakelaar H stelt u de waarden in met behulp van de Q knop Deze instelling is enkel mogelijk als u wenst op te starten met een hoogfrequent LED A2 licht op Deze instelling duwt de gebruiker de...

Page 40: ...et deze drukschakelaar selecteert u het type ontsteking met hoogfrequent of door contact lift arc en aan n stuk door lassen of pulserend lassen De selectie verandert telkens als de knop ingedrukt word...

Page 41: ...fkorting H20 T Scherm Geeft normaal de lasspanning weer in verhouding tot het huidige lasproces Om het gebruik van het koelelement in te stellen geeft het de status van dit koelelement weer V U Select...

Page 42: ...de stekker van de gasslang van de toorts aan op het contactpunt A8 op het toestel en de gasslang van cilinder drukregelaar op het contactpunt A13 op het achterpaneel Als je een toorts gebruikt die af...

Page 43: ...ingen hebt uitgevoerd die die nodig zijn om te kunnen lassen volg de stappen die in alinea 3 1 beschreven worden Zelfs als u niet lang last moet u beslissen waar u de gegevens opslaat Om het vooraf ge...

Page 44: ...ja Alaranjado Oranje I Rosa Pink Rosa Rose Rosa Rosa Roze L Rosa nero Pink black Rosa schwarz Rose noir Rosa negro Rosa negro Roze bruin M Grigio viola Grey purple Grau violett Gris violet Gris violet...

Page 45: ......

Page 46: ...Art 118 HOOGFREQUENT STROOMKRING Art 118 35 CIRCUITO PANNELLO PANEL CIRCUIT FRONTPLATTEN PLATINE CIRCUIT PANNEAU CIRCUITO PANEL CIRCUITO PAINEL STUURPRINT 36 CIRCUITO CONNETTORE CONNECTOR CIRCUIT STEC...

Page 47: ...47 Art Items 117 118...

Page 48: ...Cod 381504 07 2015...

Reviews: