21
EN
DD52R-E-RF
Electronic position indicators
Data transmission via radio frequency
Electronic position indicators
Data transmission via radio frequency
Models all rights reserved in accordance with the law.
Always mention the source when reproducing our drawings.
The available options are:
-
ALL
(default): units of measure that can be selected: mm, inch, D
-
nodEG
: units of measure that can be selected: mm, inch
-
OFF
: the key is disabled and does not allow changing the selected measuring mode.
To program the parameters listed above, see paragraph 8.2.
7.3 Setting the absolute reference
After having selected the absolute measuring mode and stopped the shaft in the
starting position or in the reference position, press the key combination to set the
absolute value to the sum of the values of the parameters
OriGin
(absolute value of reference) and
OFFSET
(compensation value).
The value of compensation (offset) allows you to adjust the value shown on the
display in such a way that takes into account, for example, wear or tool change.
The system allows you to store up to 10 values of compensation. Press the key
combination
+
. The screen will display the last compensation value
used (eg
OFFS 0
). Choose the desired compensation value by pressing the key
, and then press the key
to confirm.
The screen will display the absolute value to the sum of the values of the
parameters
OriGin
and
OFFSET
.
To program the offset values, see parameter
OFFSET
of paragraph 8.2.
It is possible to change the function of the keys combination
by setting the parameter
0 _ _ 0 _ _
The available options are:
-
L_OrG
: the reference value and the compensation value are set as shown
above. Choose the desired offset among the 10 available values, then press
the key
to confirm;
-
OFF
: the keys combination
+
is not associated to any function in the
operating mode.
To program the parameters listed above, see paragraph 8.2.
+
0 _ _ 0 _ _