28
EN
DD52R-E-RF
Electronic position indicators
Data transmission via radio frequency
Models all rights reserved in accordance with the law.
Always mention the source when reproducing our drawings.
Parameter
Description
Available options
Standard
value
0 _ _ 0 _ _
Key
combination
function
+
L_OrG
: the key combination
sets the absolute value to
the sum of
OrG
+
OFFS
parameters.
OFF
: the key combination is not
assigned to any function in the
operating mode.
L_OrG
0 _ 0 _ _ _
Key
combination
function
+
tArGEt
: the keys
combination allows to load/
program on of the 32 target
positions.
OFF
: the key is not assigned
to any function in the operating
mode.
OFF
PASS
Password
ON
: the system requires the
password 22011 to enter the
programming mode.
OFF
: the system does not
require a password to enter the
programming mode.
OFF
rESEt
Setting of
parameters to
standard values
YES
: the parameters are set to
the standard values.
NO
: the parameters maintain the
values set by the user.
NO
rE
Software version
The software version is shown on
the display.
F 2.0