MPI-R10
Magnetic measuring system
Models all rights reserved in accordance with the law.
Always mention the source when reproducing our drawings.
The menu voice
_ _ _ _ 0 _ _
(see cap. 8.3) allows the user to choose one of the
following target following modes:
-
d_tArGt
(default): when a target is loaded, the display shows the actual
absolute position and the indication to reach the target as explained before.
Pressing the key
ORG
the set target position is shown.
-
d_toGo
: when a target is loaded, the display shows the distance to the set
target. If the target is not reached, the disply blinks. Pressing the key
ORG
the
display shows the actual absolute position.
It is possible to program the keys combination
SET
+
ORG
to give direct access to
the target setup selecting
tArGEt
in the menu voice
_ _ _ _ 0 _ 0
(see cap 8.3).
If a target is selected is possible to cancel it by pressing the keys combination
SET
+
ORG
and confirm the
StOP_tG
command pressing the key
SET
. To keep
the target selection press the key
mm-inch
.
7.6 Angular measurement
MPI-R10 allow to measure angular displacements. To obtain the correct
measurement, is needed to set the parameter Radius with the measure of the
radius of the arc where the magnetic band is placed.