21
Installation
EN
The adjusting buttons are located on the side of the housing and are covered
by dummy screw unions (see Fig. 1 “Components of a device”). Before the
programming or adjustment of the limit positions you must remove the dummy
screw unions with a standard screwdriver.
The electronic limit switch has the function of monitoring the position of the con-
necting rod and switching the corresponding relay contacts when the taught-in
positions are reached. These must be evaluated by your control unit and must
lead to the immediate switching-off of the motor. In the case of the optional
brake, it must be switched simultaneously (see section 4.3.1 “Optional brake”).
Furthermore, a third relay contact is provided for the display of an intermediate
position that can be randomly taught in. If the intermediate position is overrun
the relay contact changes its switching status.
Permissible adjusting range of the limit switches:
The limit switches “Retracted” and “Extended” can be adjusted via the total
stroke. You have the possibility of setting the limit positions between 0 and maxi-
mum stroke. In doing so, a minimum stroke of 10 mm has to be maintained.
4.4.1
Teach-in of the limit positions
Factory setting:
The limit positions have been preset to the dimensions defined in the order
confirmation.
If any other dimensions are required, proceed as described below.
Deletion of the limit positions:
Two limit positions are always deleted when deletion is performed and both of
them have to be taught in again afterwards.
1. Keep the two buttons for the electronic limit switch pressed simultaneously
for at least 3 s.
9
Both buttons flash.
The positions of the limit switches are deleted.
Red button:
limit position “Extended”
Green button:
limit position “Retracted”