One circuit breaker is suf

fi

 cient to disconnect the system 

from the mains supply (if only one phase and neutral is 
used). 

 

If one 

fi

 xed (stationary installed) drive system is not 

equipped with a mains cable with plug or other means 
of disconnection from the mains supply with a contact 
opening width according to the provisions of overvoltage 
category II (according to IEC 60664-1) for full disconnect, 
an isolating device of this kind must be installed into the 

fi

 xed electrical installation according to the installation 

regulations. 

 

Mains connection cables for drive systems with rubber 
hose cables (code 60245 IEC 53) must always be repla-
ced by cables of the same type. 

 

The following applies for drive systems with access to 
unprotected, movable parts after installation: Movable 
parts of the drive system must be installed at least 2.5 m 
above the ground (or another level providing access to 
the drive system). 

4 Product 

description 

The RolTop is a electromechanical tubular motor drive. 
During operation it carries out radial movements. 

 

Commissioning of the RolTop with 

elero

 installation cable 

for setting of various functions. 

 

Fabric protection system with retraction 

 

Fabric relief function (fabric protection system) 

•  The values for your RolTop model can be found on the 

name plate. 

•  Depending on torque and size, the different models of the 

RolTop are equipped with different types of braking sys-
tems. This may lead to different operating properties e. g. 
when approaching end positions. 

5 Installation 

CAUTION 

Risk of injury due to hot surfaces. 

The drive system gets hot during operation, therefore the 
housing may be hot. Risk of skin burns. 

 

Wear personal protective equipment (protective gloves). 

Due to potential material defects, a broken gear unit, drive 
or coupling defect may cause injuries from impacts or 
shocks. 

 

For design of the system, suitable materials were used 
and a sampling test in form of a double load test accor-
ding to DIN EN 60335-2-97 was carried out. 

Risk of injury from impacts or shocks due to incorrectly 
installed or not properly engaged motor bearings. Risk due 
to insufficient stability and stored energy (gravity). 

 

Selection of motor bearings according to torque speci

fi

 -

cations. 

 

The drive system must be secured with all provided 
safety equipment. 

 

Inspection for proper engagement on the motor bearing 
and correct screw tightening torques. 

WARNING 

Risk of injury due to electricity. 

Risk of electric shock. 

 

Electrical work must only be carried out by authorized 
electricians. 

4 | US+CA 

© 

elero

 GmbH

 

Product description | Installation 

 

The system must be regularly checked for imbalance or 
signs of wear or damaged cables and springs (if appli-
cable). 

3.7 

Safety instructions on transport, 
assembly and installation 

In general, the respective transport company is responsible 
for transporting the product. The following safety require-
ments must be observed during transport, assembly and 
installation of the product: 

 

During transport, the product must be secured according 
to the regulations of the used means of transport. 

 

For transport, only hoisting equipment and suspension 
gear must be used that are appropriately dimensioned 
for safely handling the forces occurring during loading, 
unloading and assembly of the product. 

 

Only points de

fi

 ned for hoisting or suspension at the 

pallet and the product must be used for hoisting or sus-
pension. 

 

If work must be carried out under suspended parts or 
working equipment, these must be secured against falling 
by suitable means. It must be ensured by suitable hois-
ting equipment that loads drift unintentionally, fall or get 
unhooked unsupervised. 

 

Standing under suspended loads is forbidden. 

 

During loading with hoisting equipment, a safety helmet 
must be worn. 

 

Assembly and installation must generally only be carried 
out by trained and suitably instructed specialists. 

 

The rated torque and the rated operating time must be 
suitable for the properties of the driven component („fa-
bric“). 

 

The smallest internal tube diameter for the winding shaft 
is 36 mm for RolTop type S, 47 mm for RolTop type M 
and 58 mm for RolTop type L. 

 

Access to the drive system must be ensured by a freely 
accessible appropriately sized inspection 

fl

 ap that can 

easily be opened. 

3.8 

Safety instructions on operation 

 

Before initial commissioning, the operator is obliged to 
inspect the product for safe and proper operation. 

 

Inspections must also be carried out during operation of 
the product in regular intervals de

fi

 ned by the operator. 

3.9 

Safety instructions on electrical installation 

 

Work on the electric system of the used equipment must 
only be carried out by authorized electricians according to 
applicable rules and regulations by the trade association, 
particularly the provisions of DIN VDE 0100. Additionally, 
the national legal regulations of the respective country of 
operation must be observed. 

 

In case of defects like loose connections or defective or 
damaged cables on the system, the product must not put 
into operation. 

 

Prior to any inspection, installation or disassembly work, 
the system (blinds, shutter) must be disconnected from 
the voltage. 

 

All electrical connections, safety equipment, safeguards 
etc. must be properly installed, connected and grounded. 

 

The power connection must be designed according to the 
information in the electrical circuit diagram (type and level 
of voltage). 

Summary of Contents for RolTop M

Page 1: ...ety information in these operating instructions are based on currently applicable laws and regulations in Germany All information in the operating instructions must be obser Table of contents 1 Operat...

Page 2: ...drive computation program http elero com en service drive computation program htm Other applications must be approved in advance by the ma nufacturer elero GmbH Antriebstechnik refer to Address The op...

Page 3: ...The operator is obliged to only operate the product in technically flawless and operationally safe condition The operator must ensure that apart from the safety instruc tions in the operating instruc...

Page 4: ...st be regularly checked for imbalance or signs of wear or damaged cables and springs if appli cable 3 7 Safety instructions on transport assembly and installation In general the respective transport c...

Page 5: ...RolTop only to the provided mounting elements Firmly mounted control units must be visible attached The fabric must be mounted on the winding shaft The profile tube must have sufficient clearance to...

Page 6: ...s lost Important Complete uninterrupted up and down movement is neces sary to adapt the fabric protection system to the fabric Changing deleting of end positions 1 In a medium fabric position using th...

Page 7: ...the fabric has reached the desired upper end position to upper limit stop The drive system starts stops briefly and starts again as long as the UP button is pressed The drive system automatically stop...

Page 8: ...settings Troubleshooting Repair 5 6 9 Option D Upper end position freely configurable fixed lower end position Option D Upper end position freely configurable fixed lower end position In a medium fab...

Page 9: ...C Declaration of Conformity EG KONFORMIT TSERKL RUNG Wir erkl ren hiermit dass das die nachfolgend genannte n Produkt e der Maschinenrichtlinie 2006 42 EG entspricht entsprechen Produktbezeichnung Roh...

Page 10: ...Technical modifications reserved elero GmbH Antriebstechnik Linsenhofer Stra e 65 D 72660 Beuren info elero de www elero com Phone 49 7025 13 01 Fax 49 7025 13 212...

Reviews: