background image

Press one of the drive buttons until the drive system indica-
tes switchover to setting mode with a short automatic stop. 
Now, you can set the end positions. After setting both end 
positions, the setting mode is closed. 

5.6.1  Relief function for end position(s) 

If one end position was programmed to limit stop, an additi-
onal relief function can be activated for the fabric. 

Important 

Activation of the relief function (for options B to D) is carried 

out in one step with programming of the end positions (refer 
to sections 5.6.7 to 5.6.9)! 

5.6.2  Relief function at the upper stop 

For option B (refer to section 5.6.7) 
and option C (refer to section 5.6.8): 
Activating the relief function at the upper limit stop 

Using the installation cable, keep the 

UP

 button 

 

pressed from step 

 (section 5.6.7 and 5.6.8) and 

press additionally (simultaneously) the 

DOWN

button 

. Keep both buttons pressed until the fabric stops. 

The relief function at the upper limit stop is activated. 

5.6.3  Relief function at the lower stop 

For option C (refer to section 5.6.8) 
and option D (refer to section 5.6.9): 
Activating the relief function at the lower limit stop 

Using the installation cable, keep the 

DOWN

 button 

 pressed from step 

 (section 5.6.8 and 5.6.9) 

and press additionally (simultaneously) the 

UP

button 

.Keep both buttons pressed until the fabric stops. 

The relief function at the lower limit stop is activated. 

5.6.4  Changing / deleting of end positions 

and deleting the relief function 

It is not possible to change or delete one individual end 
position. This is always carried out in pairs (upper and lower 
end position at once). 

By deleting the end positions, also the setting of the optio-
nal relief function is lost. 

Important 

Complete, uninterrupted up and down movement is neces-
sary to adapt the fabric protection system to the fabric. 

Changing / deleting of end positions 

In a medium fabric position, using the installation 
cable, simultaneously press both direction buttons (

 

and 

) and keep them pressed until the drive system 

brie

fl

 y moves up and down. 

Deleting the end position settings is completed. 
The end positions can be reset. 

6 | US+CA  

© 

elero

 GmbH

 

Installation: Electrical connection | End position settings 

5.3 

Connection example, RolTop 120 V / 60 Hz 

PE

N

L1

1 0 2

sw

br

bl

gr

/g

e

1

2

3

4

7

6

5

3

2

1

3

2

1

Fig. 5    Circuit diagram RolTop 120 V / 60 Hz and 

Wiring when using a Hirschmann plug connection 
STAS-3 

Important 

The motor controls in up and down direction must be inter-
locked. 

5.4 Parallel 

connection 

Important 

You can connect several RolTop systems in parallel. To do 
so, please observe the maximum control capacity. 

5.5 Commissioning 

Important 

On delivery, the drive system is set to commissioning mode. 

 

It is necessary to set the end positions with the 

elero

 

installation cable. 

 

Connecting the installation cable is only for commissio-
ning of the drive system and for con

fi

 guration.

Blau (Neutralleiter)  

(1)

Schwarz  

(2)

Braun  

(3)

Grün-gelb 

ele

ro

Blau (Neutralleiter)  

(1)

Schwarz  

(2)

Braun  

(3)

Grün-gelb 

Fig. 6  Installation cable connection 

 

Switch on power supply. 

 

Now, you can set the end positions with the 

elero

 instal-

lation cable. 

5.6 

End position and relief settings 

Important preliminary consideration: 

Before carrying out the end position settings, decide on 
a certain relief function (different combinations available 
according to the following models). 

This will save you unnecessary time and effort during con-

fi

 guration! 

1

 Winding thermostat 

2

 Device switch 

3

 Junction box 

4

 Switch box 

5

  Shutter switch / 

Shutter button 

6

 Electronic 

7

 Condenser 

sw

  

black 

br

  

brown 

bl

  

blue 

gr/ge

  

green / yellow 

Summary of Contents for RolTop M

Page 1: ...ety information in these operating instructions are based on currently applicable laws and regulations in Germany All information in the operating instructions must be obser Table of contents 1 Operat...

Page 2: ...drive computation program http elero com en service drive computation program htm Other applications must be approved in advance by the ma nufacturer elero GmbH Antriebstechnik refer to Address The op...

Page 3: ...The operator is obliged to only operate the product in technically flawless and operationally safe condition The operator must ensure that apart from the safety instruc tions in the operating instruc...

Page 4: ...st be regularly checked for imbalance or signs of wear or damaged cables and springs if appli cable 3 7 Safety instructions on transport assembly and installation In general the respective transport c...

Page 5: ...RolTop only to the provided mounting elements Firmly mounted control units must be visible attached The fabric must be mounted on the winding shaft The profile tube must have sufficient clearance to...

Page 6: ...s lost Important Complete uninterrupted up and down movement is neces sary to adapt the fabric protection system to the fabric Changing deleting of end positions 1 In a medium fabric position using th...

Page 7: ...the fabric has reached the desired upper end position to upper limit stop The drive system starts stops briefly and starts again as long as the UP button is pressed The drive system automatically stop...

Page 8: ...settings Troubleshooting Repair 5 6 9 Option D Upper end position freely configurable fixed lower end position Option D Upper end position freely configurable fixed lower end position In a medium fab...

Page 9: ...C Declaration of Conformity EG KONFORMIT TSERKL RUNG Wir erkl ren hiermit dass das die nachfolgend genannte n Produkt e der Maschinenrichtlinie 2006 42 EG entspricht entsprechen Produktbezeichnung Roh...

Page 10: ...Technical modifications reserved elero GmbH Antriebstechnik Linsenhofer Stra e 65 D 72660 Beuren info elero de www elero com Phone 49 7025 13 01 Fax 49 7025 13 212...

Reviews: