background image

5.3 

Connection example, RolTop-915 120 V / 60 Hz 

N
PE

L1

sw

br

bl

gr

/g

e

3

2

1

Fig. 5    Circuit diagram RolTop-915 120 V / 60 Hz and 

Wiring when using a Hirschmann plug connection 
STAS-3 (with bridge) 

5.4 Parallel 

connection 

Important 

You can connect several RolTop-915 systems in parallel. To 
do so, please observe the maximum control capacity. 

5.5 Commissioning 

Important 

On delivery, the drive system is set to commissioning mode. 

 

It is necessary to set the end positions with the 

elero

 

installation cable (refer to 

fi

 g. 6) or a 

elero

 wand/hand 

transmitter (refer to 

fi

 g. 7).  

 

Connecting the installation cable is only for commissio-
ning of the drive system and for con

fi

 guration. 

5.5.1  Installation cable connection 

blue (neutral) 

(1)

black 

(2)

brown 

(3)

green-yellow 

Fig. 6  Installation cable connection 

 

Switch on power supply. 

 

Now, you can set the end positions with the 

elero

 instal-

lation cable. 

1

 Winding thermostat

 

2

 Device plug

 

3

 

 Junction box 

(outside of roller shutter case) 

4

 Electronic

 

5

 Condenser

 

sw

  

black 

br

 brown 

bl

  

blue 

gr/ge

  

green/yellow

6 | US+CA  

© 

elero

 GmbH

 

Installation: Electrical connection

5.2 Electrical 

connection 

WARNING 

Danger to life due to incorrect electrical connection. 

Risk of electric shock. 

 

Before initial commissioning, check the correct connec-
tion of the PE conductor. 

NOTE 

Damage to the RolTop-915 due to incorrect electrical con-
nection. 

 

Before initial commissioning, check the correct connec-
tion of the PE conductor. 

Damage to or destruction of the RolTop-915 due to ingress 
of humidity. 

 

For devices with protection class IP44, the customer-
provided connection of cables or plugs (wiring) must also 
be compliant with protection class IP44. 

Damage to or destruction of the RolTop-915 for models 
with 120 V 1 AC due to incorrect control. 

 

Switches that are preset to OFF (dead man) for drive 
systems must be mounted in viewing range of the Rol-
Top-915 but away from moving parts and at a height 
above 1.5 m. 

Important 

For electrical connection, generally no connection and dis-
connection of the connection cable or plug is necessary. 

Particularly at the RolTop915 type S and depending on the 
used mounting or adapter plate, it is necessary to remove 
this screwed plate before replacing cables. 

Only connect when the system is disconnected from 
the voltage. To do so, disconnect the drive cable. 

1  Use a suitable screwdriver to push the locking mecha-

nism of the device plug to the cable.

 

2  Disconnect the plug.

 

3  Insert the device plug until the locking mechanism enga-

ges.

 

Removing and inserting the device plug 

Delivery con-
dition 

Remove plug 

Insert plug 

Fig. 4  Removing and inserting the device plug 

1

2

3

Summary of Contents for RolTop-915

Page 1: ... misuse 2 2 4 Warranty and liability 2 2 5 Customer service of the manufacturer 2 3 Safety 2 3 1 General safety instructions 2 3 2 Layout of safety instructions 2 3 3 General safety principles 3 3 4 General obligations of the operator 3 3 5 General requirements on personnel 3 3 6 Safety instructions on technical condition 4 3 7 Safety instructions on transport assembly and installation 4 3 8 Safet...

Page 2: ...t from the safety instructions in these operating instructions applicable local regulations on pre vention of accidents environmental protection and occupa tional safety must be observed Regulations and standards for safety assessment can be found in the EC Declaration of Conformity 2 2 Intended use This product is intended for use in facade construction for driving electrical sun protection devic...

Page 3: ... in the country of operation and other binding regulations on ope rational safety prevention of accidents and environmental protection are complied with All work on the product must only performed by trained safety related instructed and authorized personnel Appropriately qualified personnel must observe all appli cable standards and regulations in the country of installation and inform the custom...

Page 4: ... Product description 3 6 Safety instructions on technical condition Prior to installation the product must be checked for damage and proper condition The operator is obliged to only operate the product in technically flawless and operationally safe condition The technical condition must comply with statutory require ments applicable at the date of manufacturing stated on the name plate If dangers ...

Page 5: ...iately after removing the Rol Top 915 from its original packaging The drive system must be installed in a position safe from rain Important On delivery factory settings the RolTop 915 is in commis sioning mode It is necessary to set the end positions refer to section 5 6 Optimum use of the wireless signal Position the antenna as freely as possible and reposition it in case of bad reception Do not ...

Page 6: ... initial commissioning check the correct connec tion of the PE conductor NOTE Damage to the RolTop 915 due to incorrect electrical con nection Before initial commissioning check the correct connec tion of the PE conductor Damage to or destruction of the RolTop 915 due to ingress of humidity For devices with protection class IP44 the customer provided connection of cables or plugs wiring must also ...

Page 7: ...n D refer to section 5 6 9 Activating the relief function at the lower limit stop 1 In a medium fabric position using the installation cable or a programmed transmitter keep the DOWN button pressed from step section 5 6 8 and 5 6 9 and press additionally simultaneously the UPbutton Keep both buttons pressed until the fabric stops The relief function at the lower limit stop is activated 5 6 4 Chang...

Page 8: ...omatically The lower end position is set Optional Activation of the relief function for the lower limit stop refer to section 5 6 3 End position setting of option D is completed Fig 12 End position setting option D 8 US CA elero GmbH End position settings 5 6 7 Option A Upper and lower end position freely configurable Option A Upper and lower end position freely configurable In a medium fabric pos...

Page 9: ...ric stops briefly moves on stops and moves downwards 5 On the additionally transmitter to be program med immediately max 1 second after start of a down movement press the DOWNbutton The status indicator flashes briefly The drive system stops Programming of the additional transmitter is complete Stopping the bidirectional wireless programming mode Press the STOP button for at least 6 seconds until ...

Page 10: ...en Produktbezeichnung Rohrmotor RolTop S 915 120V 60Hz alle Varianten RolTop M 915 120V 60Hz alle Varianten Beschreibung Einsteckantrieb für Rollläden mit 915 MHz Funkempfänger Die Übereinstimmung der s bezeichneten Produkte s mit den wesentlichen Schutzanforderungen wird durch Einhaltung folgender Richtlinien und Normen berücksichtigt R TTE Richtlinie 1999 5 EG Niederspannungsrichtlinie 2006 95 E...

Reviews: