elero RolMotion M-868 Operating And Assembly Instructions Manual Download Page 7

5.5.5  Variant C: Fixed upper and lower limit stop 

Variant C: Fixed upper and lower limit stop 

① 

Starting from a central blind position, press the  

[

UP 

▲] button with the assembly cable or a 

programmed transmitter until the blind has reached the 

upper end position (travels to the upper limit stop). 

The drive begins to travel, briefly stops and travels 

further (for as long as the [

UP 

▲] button remains 

pressed). 

The drive switches off automatically when the upper 

limit stop is reached. 

② 

Press the [

DOWN/CLOSE 

▼] button until the drive 

stops automatically. 
The upper end position has been set. 

③ 

Press the [

DOWN/CLOSE 

▼] button again until the 

blind has reached the desired end position (travels 

to the lower limit stop). 

The drive begins to travel, briefly stops and travels 

further (for as long as the [

DOWN/CLOSE 

▼] button 

remains pressed). 

The drive switches off automatically when the lower 

limit stop is reached. 

④ 

Press the [

UP 

▲] button until the drive stops 

automatically. 
By default, the lower end position has been set. 
Non-standard setting for placement of the blind slats 

at the lower end position: See chapter 5.6. 

Adjustment of the variant C end position is complete. 

5.5.6  Variant D:  Upper end position freely 

adjustable, fixed lower limit stop 

Variant D: Upper end position freely adjustable, 

fixed lower limit stop 

① 

Starting from a central blind position, press the [

UP 

▲] button with the assembly cable or a programmed 

transmitter until the blind reaches the desired upper 

end position. 

The drive begins to travel, briefly stops and travels 

further (for as long as the button remains pressed). 

You can make corrections using the [UP ▲] and 

[DOWN/CLOSE ▼] buttons. 

② 

Press the [

DOWN/CLOSE 

▼] button until the drive 

stops automatically. 
The upper end position has been set. 

③ 

Press the [

DOWN/CLOSE 

▼] button again until the 

blind has reached the desired end position (travels 

to the lower limit stop). 

The drive begins to travel, briefly stops and travels 

further (for as long as the [DOWN/CLOSE ▼] button 

remains pressed). 

The drive switches off automatically when the lower 

limit stop is reached. 

④ 

Press the [

UP 

▲] button until the drive stops auto

-

matically.

By default, the lower end position has been set. 
Non-standard setting for placement of the blind slats 

at the lower end position: See chapter 5.6. 

Adjustment of the variant D end position is complete. 

5.6  Placement of the roller blind slats 

For slow lowering of the roller shutter bars, a standard 

travel path is set after setting the end positions. 
It is possible to change this position when the end positions 

have been programmed: 
•  After the blind starts to rise from the lower end position, 

hold down the [

UP

▲] button until the drive starts to move 

further up after approx. 2 seconds. As soon as the lowest 

blind slat is raised from the lower limit stop, release the 

[

UP

▲] button. This is now the position from which slow 

downward travel commences. 

5.7  Program the transmitter 

Important 

Precondition: The drive must be in radio operation mode. 

 

If the end positions have not been programmed, remove 

the blind from the winding shaft. 

5.7.1 

Programming the first transmitter 

Programming the (first) transmitter 

Operating procedure 

Result 

Switch the power off and 

on again 

The drive is in 

learning mode for 

approximately  

5 minutes. 

Press the programming 

button 

P

 on the transmitter 

to be programmed for 

approximately 1 second. 

The status display 

lights up. The drive is 

now in learning mode 

(up/down travel) for 

approximately  

2 minutes. 

Immediately (maximum  

1 second) after the start of 

upward travel, press the 

[

UP 

▲] button. 

The status display 

lights briefly. The blind 

stops briefly, starts 

moving again and then 

moves downwards. 

4

Immediately (maximum  

1 second) after the start of 

downward travel, press the 

[

DOWN/CLOSE 

▼] button. 

The status display 

lights briefly. The drive 

will stop.

The (first) transmitter is now programmed. 

5.7.2  Programming additional transmitters 

Up to 16 transmitters can be programmed. 

Programming additional transmitters 

Operating procedure 

Result 

On an 

already programmed 

transmitter,

 hold down 

the buttons [

UP 

▲] + 

[

DOWN/CLOSE 

▼] + [

P

(programming button) 

simultaneously for 

approximately 3 seconds. 

The status display 

lights up.

The drive is in 

learning mode for 

approximately  

5 minutes. 

(alternative to the previous 

line)

Switch the power off and 

on again 

The drive is in 

learning mode for 

approximately  

5 minutes. 

On the 

(additional) 

transmitter to be 

programmed,

 press the 

programming button [

P

]. 

The status display 

lights briefly. The drive 

is in learning mode 

(up/down travel) for 

approximately  

2 minutes. 

 © 

elero

 GmbH

  

EN | 7

End position settings 

Summary of Contents for RolMotion M-868

Page 1: ...documentation Other information shall remain unaffected by these provisions Contents 1 Operating and assembly instructions 1 2 General information on these instructions 1 2 1 Standards and guidelines...

Page 2: ...he declaration of conformity see EC Declaration of Conformity All information relating to safety in these operating instructions refers to the laws and regulations that are currently valid in Germany...

Page 3: ...l detection simple obstacle detection of drive shaft Relief function for the blind blind protection Cyclical reference runs compensate for changes in the winding behaviour of the roller blind slats In...

Page 4: ...GmbH Assembly Mechanical fastening Electrical connection Suitable materials have been used for the engineering design and random sample testing by means of a double load test has been performed in acc...

Page 5: ...cable see Fig 6 or an elero wall or hand held transmitter see Fig 7 The assembly cable may only be connected to commission the drive and for adjustment operations 5 4 1 Connection for assembly cable...

Page 6: ...y By default the lower end position has been set Non standard setting for placement of the blind slats at the lower end position See chapter 5 6 Adjustment of the variant B end position is complete 6...

Page 7: ...or placement of the blind slats at the lower end position See chapter 5 6 Adjustment of the variant D end position is complete 5 6 Placement of the roller blind slats For slow lowering of the roller s...

Page 8: ...hen moves downwards 4 On the additional transmitter to be program med press the DOWN CLOSE button immediately within 1 second after the blind starts moving downwards The status display lights briefly...

Page 9: ...nt regulations when you no longer need it Disposal is partially subject to applicable legal regulations Bring the product to be disposed of to authorised collection points only Environmental informati...

Page 10: ...t mode 1 min 14 14 14 14 Rated speed whisper mode 1 min 5 5 5 5 Rated voltage V 1 230 1 230 1 230 1 230 Rated frequency Hz 50 50 50 50 Noiseless soft brake Rated current A 0 4 0 5 Rated power consumpt...

Page 11: ...E E 45 O 55 C D 33 33 C D 33 E 45 O 45 O 45 O C D 33 45 O O 57 5 E C D 33 45 O O 57 5 E 29 O 49 5 O 49 5 E E C D 33 33 C D 33 E 45 O 45 O C D 33 45 O O 57 5 E C D 33 45 O O 57 5 E 29 O 49 5 O 49 5 C D...

Page 12: ...We reserve the right to make technical changes elero GmbH Drive technology Maybachstr 30 73278 Schlierbach Germany info elero de www elero com...