elero RolMotion M-868 Operating And Assembly Instructions Manual Download Page 4

5.1  Mechanical fastening 

Important preliminary consideration: 

The working area around the installed drive is usually 

very small. For this reason, obtain an overview of how the 

electrical connection has been implemented prior to the 

mechanical installation (see section 5.2) and make the 

necessary changes beforehand. 

NOTICE 

Crushing or tension will damage the electrical cables. 

 

Install all electrical cabling so that it is not subject to any 

crushing or tensile load 

 

Observe the bending radii of cables (at minimum 50 mm). 

 

Route connecting cables in a downward loop to prevent 

water running into the drive. 

Damage to the drive due to the effect of impact forces. 

 

Slide the drive into the shaft. Never knock the drive in or 

use force! 

 

Take care not to drop the drive! 

Damage or destruction to the drive by drilling. 

 

Never drill the drive! 

Important 

Only fasten the RolMotion M-868 to the designated 

fastening elements. 
Fixed installed control devices need to be attached so they 

are visible. 
•  The blind must be attached to the winding shaft. 
• 

The profile tube must have sufficient clearance from the 

motor tube. 

• 

Make sure there is sufficient axial play (1 - 2 mm) 

Installation in profile tubes

 

Ⓐ 

Push drive with relevant adapter and 

crown into the profile tube.

Install the motor cable so it is 

protected to prevent damage from 

the driven part. 

Ⓑ 

Secure the counterpart support to 

prevent axial movement, e.g. screw 

or rivet on the idler.

Secure the drive axially in the 

support! 

Ⓒ Attach the blind to the shaft.

 

Only operate the drive horizontally, as intended, with the 

connection cable leading out from the side and out of the 

blind winding area. 

5.2  Electrical connection 

WARNING 

Faulty electrical connections constitute a fatal hazard. 
Risk of electric shock. 

 

Prior to initial commissioning, check the PE wire is 

correctly connected. 

NOTICE 

Damage to the RolMotion M-868 due to incorrect electrical 

connection. 

 

Prior to initial commissioning, check the PE wire is 

correctly connected. 

B

A

C

4 | EN 

© 

elero

 GmbH 

Assembly | Mechanical fastening | Electrical connection 

 

Suitable materials have been used for the engineering 

design and random sample testing by means of a double 

load test has been performed in accordance with DIN EN 

60335-2-97. 

Risk of injury due to knocks or impact triggered by motor 

bearings that are incorrectly mounted or engaged. Hazard 

due to insufficient stability or steadiness and accumulated 

energy (gravity). 

 

►Selection of motor bearing by torque specifications. 

 

The drive must be protected with all the enclosed safety 

devices. 

 

Check for correct engagement on motor bearing and the 

correct screw tightening torques. 

WARNING 

Risk of injury due to electric current. 
Risk of electric shock. 

 

Always have electrical work carried out by an authorised 

electrician. 

Risk of injury due to electric current. 
Possible danger due to parts that are faulty becoming 

energised. 

 

Electrical connection is described in the operating and 

assembly instructions, including cable routing. 

CAUTION 

Risk of injury due to malfunctions as a result of incorrect 

assembly. 
Drive is overwound and may destroy parts of the 

application. 

 

For safe operation, the end positions must be set/taught 

in. 

 

Manufacturer training is available for specialist 

companies. 

NOTICE 

Power failures, breaking of machine parts and other 

malfunctions. 

 

For safe operation, assembly must be correct and the 

end position adjustments will have to be carried out upon 

commissioning. 

Damage to RolMotion M-868 due to ingress of moisture 

 

On devices with protection class IP 44, the ends of all 

cables or plugs will need to be protected from ingress 

of moisture. This measure needs to be implemented 

immediately after removing the RolMotion M-868 from the 

original packaging. 

 

The drive must be installed in such a way that it cannot 

get wet. 

Important 

In its delivery condition (factory setting), the RolMotion 

M-868 will be in commissioning mode. 

 

The end positions will need to be set (see 

section 5.6). 

Optimal use of the radio signal. 

 

Extend the antenna as far as possible. If reception is 

poor, adjust the antenna. 

 

Do not kink, shorten or extend the antenna. 

 

Do not position the two radio drives closer than the 

minimum distance of 15 cm. 

Summary of Contents for RolMotion M-868

Page 1: ...documentation Other information shall remain unaffected by these provisions Contents 1 Operating and assembly instructions 1 2 General information on these instructions 1 2 1 Standards and guidelines...

Page 2: ...he declaration of conformity see EC Declaration of Conformity All information relating to safety in these operating instructions refers to the laws and regulations that are currently valid in Germany...

Page 3: ...l detection simple obstacle detection of drive shaft Relief function for the blind blind protection Cyclical reference runs compensate for changes in the winding behaviour of the roller blind slats In...

Page 4: ...GmbH Assembly Mechanical fastening Electrical connection Suitable materials have been used for the engineering design and random sample testing by means of a double load test has been performed in acc...

Page 5: ...cable see Fig 6 or an elero wall or hand held transmitter see Fig 7 The assembly cable may only be connected to commission the drive and for adjustment operations 5 4 1 Connection for assembly cable...

Page 6: ...y By default the lower end position has been set Non standard setting for placement of the blind slats at the lower end position See chapter 5 6 Adjustment of the variant B end position is complete 6...

Page 7: ...or placement of the blind slats at the lower end position See chapter 5 6 Adjustment of the variant D end position is complete 5 6 Placement of the roller blind slats For slow lowering of the roller s...

Page 8: ...hen moves downwards 4 On the additional transmitter to be program med press the DOWN CLOSE button immediately within 1 second after the blind starts moving downwards The status display lights briefly...

Page 9: ...nt regulations when you no longer need it Disposal is partially subject to applicable legal regulations Bring the product to be disposed of to authorised collection points only Environmental informati...

Page 10: ...t mode 1 min 14 14 14 14 Rated speed whisper mode 1 min 5 5 5 5 Rated voltage V 1 230 1 230 1 230 1 230 Rated frequency Hz 50 50 50 50 Noiseless soft brake Rated current A 0 4 0 5 Rated power consumpt...

Page 11: ...E E 45 O 55 C D 33 33 C D 33 E 45 O 45 O 45 O C D 33 45 O O 57 5 E C D 33 45 O O 57 5 E 29 O 49 5 O 49 5 E E C D 33 33 C D 33 E 45 O 45 O C D 33 45 O O 57 5 E C D 33 45 O O 57 5 E 29 O 49 5 O 49 5 C D...

Page 12: ...We reserve the right to make technical changes elero GmbH Drive technology Maybachstr 30 73278 Schlierbach Germany info elero de www elero com...