background image

 

Ⓒ 

elero GmbH 

 

EN  |  17   

16 | EN  

 elero GmbH 

No.  wire 

color  

Designa-

tion 

Assignment 

black 

-

 

0 V supply control elements 

8  red 

+

 

+ 8.4 ... 12 V DC 

 

supply control elements 

Table 3: Assignment control elements 

Insulate unused wires against contact. 
Do not connect the control cables to the circuit board 

until the wiring has been completed. 

Preparation 

5.1  Product contents 

Designation 

Fig. 

ExitSafe 

Article-No. 283880001 

Complete unit shown in 

installation double-box  

(not included) 

Control module ExitSafe-S 

Designation 

Fig. 

Battery pack ExitSafe-A 

Article-No. 283881201  

(replacement) 

Connection cable  

for control elements 

Article-No. 221470001 

User manual 

Article-No. 181234601 

Retain for future use. 

Table 4: Product contents 

5.2  Optional accessories 

Designation 

Fig. 

Extension 2,2 m for JA drives 

 

(4 wires with QuickOn plug) 

Article-No. 221470001 

Important: Use a maximum 

of 1 extension per drive (total 

length maximum 3 m). 

 

 

Summary of Contents for ExitSafe 28 388.0001

Page 1: ...181234601_EN_0119 ExitSafe 28 388 0001 Operating instructions Retain for future reference...

Page 2: ...tions of the original version All rights reserved in the event case of patent utility model or design registrations Contents 1 Introduction 4 2 Safety instructions 5 3 System description 9 4 Technica...

Page 3: ...h a low level of risk possibly resulting in minor injuries NOTICE Danger possibly resulting in damage to property 2 Safety instructions 2 1 Target group This document is primarily intended for use by...

Page 4: ...r handling of the ExitSafe Use the packaging enclosed Handle the components of the ExitSafe carefully Avoid transporting fully charged battery packs Observe the permitted storage temperature Avoid imp...

Page 5: ...er shutters venetian blinds and rolling doors ExitSafe may be used if the function of one tubular motor has not yet been enabled even in the event of a failure in the 230 V mains supply of a building...

Page 6: ...via the mains connection which is used to recharge the battery pack 3 3 2 Battery pack ExitSafe A The battery pack ExitSafe A stores the power requi red to operate the ExitSafe The battery pack conta...

Page 7: ...module type plate Type plate ExitSafe A B C D E 1 1 Diese Ma e werden besonders gepr ft Allgemeintoleranzen Ma stab Scale Solid Edge 29 6 elero GmbH Maybachstrasse 30 73278 Schlierbach www elero com...

Page 8: ...or Supply 2 white 8 4 12 V DC motor supply 3 red brown Signal DOWN CLOSE for motor 4 brown red Signal UP for motor Table 2 Assignment motor terminals The ExitSafe is controlled by potential free conta...

Page 9: ...ontents Designation Fig ExitSafe Article No 283880001 Complete unit shown in installation double box not included Control module ExitSafe S Designation Fig Battery pack ExitSafe A Article No 283881201...

Page 10: ...r control Master control has priority over individual control DIP switch No Function position OFF Function position ON 2 After 2 years of ope ration or 500 charging cycles of the battery pack a warnin...

Page 11: ...eing used are to be insulated 3 Connect the motor with original connection cable to the four pole screw terminal of the control module The sense of rotation of the motor can be adjusted by exchanging...

Page 12: ...approx 180 s and can be terminated earlier via a short input pulse Switch 4 OFF Push button mode The motor is only activated as long as an input is operated This is helpful if a connected command init...

Page 13: ...e complete movement of the motor can be guaranteed Automatic start up can be set using DIP switch 3 Switch 3 OFF No automatic start up An acoustic signal is emitted only in the case of a low battery p...

Page 14: ...sary contact your supplier 8 Decommissioning and disposal 8 1 Disassembly WARNING Risk of injury and damage due to unconnected electrical cables WARNING The electrical connection may only be modified...

Page 15: ...rmity is available at the following Internet address www elero com downloads service downloads 9 2 Legal Disclosure elero GmbH Maybachstr 30 73278 Schlierbach GERMANY Telephone 49 0 7021 9539 0 Email...

Page 16: ...www elero de...