5.3 Packing
The packaging has been designed to protect the
ExitSafe during transport by freight carrier or parcel
delivery service. After unpacking, please check all
delivered components for completeness or damage.
The packaging must be disposed of separately in
accordance with the applicable rules for cardboard
and plastic.
5.4 Settings
The ExitSafe-S control module has six DIP switches to
set the functions listed in Table 5. These settings should
be configured before installing the ExitSafe.
DIP switches
Default setting:
All 6 DIP switches
in the OFF position.
DIP switch
No.
Function
position OFF
Function
position ON
1
Individual control has
priority over master
control
Master control has
priority over individual
control
DIP switch
No.
Function
position OFF
Function
position ON
2
After 2 years of ope
-
ration or 500 charging
cycles of the battery
pack, a warning signal
will sound.
No warning signal will
sound after 2 years
of operation or 500
charging cycles of the
battery pack.
3
When the battery
pack is low, the motor
will not be controlled
automatically.
When the battery
pack is low, the mo
-
tor will be controlled
automatically.
4
Push-button mode
Maintained mode
operation.
5
Maintained mode is
active immediately.
Maintained mode is
active after a delay.
6
Normally open contact
at the input signal ▲
.
Normally closed con
-
tact at input signal ▼
(wire breakage recog
-
nition).
Table 5: Settings overview
5.5 Connection and installation
WARNING
Risk of injury, damage to the ExitSafe and
damage to the area surrounding the ExitSafe
due to improper electrical connections.