The Combio-868 RM /-915 for elero tubular motors with plug-

in cable (limit switch drive)

1. Switch off the mains voltage.
2.   Press the locking mechanism of the drive plug towards the 

cable with a screwdriver.

3.  Pull out the plug.
4.  Plug the motor cable of the radio receiver into the drive.
5.   Connect the mains cable of the Combio-868 RM /-915 correctly 

with the mains voltage.

RM /-915

Combio-868

PE

L

N

Antenna

1~

M

Mains

230 V/50 Hz

6. Fasten the radio receiver.
7. Switch the mains voltage on again.
8.  Programme the transmitter (→ refer to the transmitter   

 instructions).

9. Mount the hangings and set the limit switch.

  Pin 

Wire colour

  designation  230 V
 L 

Brown

 N 

Blue

 PE 

Green/yellow

Connection and installation

Combio-868 RM /-915 for tubular motors with plug-in cable  

(ACS-E electronic drive)

1. Switch off the mains voltage.
2.   Press the locking mechanism of the drive plug towards the 

cable with a screwdriver.

3.  Pull out the plug.
4.   Plug the motor cable of the radio receiver into the drive.
5.   Connect the mains cable of the Combio-868 RM /-915 correctly 

with the mains voltage.

RM /-915

Combio-868

PE

L

N

combio868rm

Antenna

1~

M

Mains

230 V/50 Hz

6. Fasten the radio receiver.
7.  Switch the mains voltage on again.
8.  Programme the transmitter (→ refer to the transmitter 

 instructions).

 

Note: 

  Rotate the winding shaft manually in the corresponding 

direction.

9.  Mount the hangings and operate the drive in the self-program-

ming mode.

  Pin 

Wire colour

  designation  230 V
 L 

Brown

 N 

Blue

 PE 

Green/yellow

Note:

  Do not shorten or lengthen 

the antenna.

Summary of Contents for Combio-868 JA Pulse/-915

Page 1: ...868 915 Combio 868 JA 915 28500 0006 Combio 868 RM 915 28520 0006 Combio 868 RM RevoLine 915 28525 0006 Combio 868 JA Pulse 915 28505 0006 Operating instructions translation Please take care of the op...

Page 2: ...13 Technical data 14 Tips for finding faults 15 Important safety indications Observe the following Instructions Danger of injury due to electric shocks Connections to the mains supply must be car ried...

Page 3: ...ations in which this risk is excluded by other safety sys tems The user does not have any protection from interferences from other telecommunication and terminal equipment e g including radio equipmen...

Page 4: ...ceiver acti vates the self locking operating mode The handheld transmitter can be used to save an intermediate position and tilting position for the slats refer to the transmitter instructions Mountin...

Page 5: ...nsmitter instructions Connection and installation Combio 868 JA 915 for venetian blind drives 1 Put the drive into operation with the installation cable and set the upper and lower limit switch 2 Move...

Page 6: ...n 230 V L Brown N Blue PE Green yellow Connection and installation Combio 868 RM 915 for tubular motors with plug in cable ACS E electronic drive 1 Switch off the mains voltage 2 Press the locking mec...

Page 7: ...Green yellow Connection and installation Combio 868 RM 915 for elero tubular motors with fixed cable CSM E electronic drive for textile sun protection Note CSM E drives must not be connected using th...

Page 8: ...H 15 Max number for transmitters 16 16 Troubleshooting Problem Cause Solution No radio reception 1 Transmitter ist not programmed 2 No mains voltage 1 Program the trans mitter 2 Switch on the mains su...

Page 9: ...mitter is in compliance with Directive 2014 53 EU The full text of the EU Declaration of Conformity is available at the following Internet address www elero de downloads service elero GmbH Antriebstec...

Reviews: