5
2
Tone Generator (CON’T)
polarity, continuity and voltage testing
• Black and red testing leads and standard 4-pin modular
cable for individual wire tests or modular jack tests
• Convenient compact size and simple application
Specifications:
• 1 ft. each of red and black test lead
• 1 ft. 4-pin modular cord and plug
• One 3-position toggle switch for operation mode control
• One 3-color LED display for line polarity, continuity and
voltage test
• One 2-position slide switch for tone volume level selection
• Power: 9V DC battery
Probe
Features:
• Special inductive plastic tip which prevents accidental
shorts (possible with copper-tip tracers) when using near
high voltage devices
• Traces and identifies wires or cables in a bundle or group
without damaging cablue insulation
• Adjustable volume level for various work environments
• Both amplifier and LED for loud or dark work environ-
ments
• Can work with any existing tone generator in the market
• Power switch to prevent battery drain
Specifications:
• Pen-style casing
• Special inductive plastic tip
• One push-button TRACE switch
• One battery low LED indicator
Operation (CON’T)
D. Sending a Tone
1. Slide the toggle switch to the “TONE” position
2. Connect the test leads to a pair of wires or
attach one lead to the ground and the other
lead to either side of the line. (See Fig. 3)
3.
4. Select either a dual alternating tone or a sin-
gle solid tone by positioning the button on the
face of the Tone Generator unit to “DUAL
TONE” or “SINGLE TONE”
5. Select one of the display functions (LED
only/speaker only/LED & speaker together)
by positioning the switch on the side of the
Probe to “L”, “S”, or “L & S” respectively
6. Use the Probe to trace the subject wire
7. Reception of tone will be loudest (amplifier)
or brightest (LED) on the subject wire
CAUTION
Do n
not cconnect tto aan aactive A
AC circuit eexceeding 224
volts iin tthis m
mode. Failure tto ffollow tthis ccaution ccould
cause ddamage tto tthe u
unit.
!!
!!