Mat Planning and Layout Instructions

6

����������

������� ��������� �������� ������ ���� �����

������

Planning your eRibbon

It is important when organising the layout of the mats that you accurately 
draw your room area as this will help save time and ensure a smooth 
installation.

The eRibbon heating mats should cover at least 65 – 80% of the floor area, the 
more coverage the less time needed to heat the area. The eRibbon mats have been 
designed with wide heating elements that are positioned closer together so that you 
can achieve comfortable temperatures more quickly providing you with a guaranteed 
even distribution of heat across your floor.
The eRibbon heating mats are available in several convenient sizes. Choose the 
combination of heating mats that best enables you to cover the recommended 
65 – 80% of your room. Plan to use the larger heating mats as much as possible and 
the smaller mats only as gap fillers.
Please find below a list of the available mat sizes complete with the resistances for 
your reference whilst installing the eRibbon.

Product Specifications

Q/F

Part Code

Dimensions

Coverage Resistance

W/m

2

1251

eRib1001

1m x 1m

1m

2

321-393

150

1251

eRib1015

1m x 1.5m

1.5m

2

207-241

225

1253

eRib1002

1m x 2m

2m

2

155-183

300

1254

eRib1025

1m x 2.5m

2.5m

2

131-153

375

1255

eRib1003

1m x 3m

3m

2

107-124

450

1256

eRib1035

1m x 3.5m

3.5m

2

100-115

525

1257

eRib5012

0.5m x 1.2m

0.5m

2

534-618

90

1258

eRib5015

0.5m x 1.5m

0.75m

2

445-516

113

1259

eRib5002

0.5m x 2m

1m

2

321-393

150

1260

eRib5025

0.5m x 2.5m

1.25m

2

253-309

187

1261

eRib5003

0.5m x 3m

1.5m

2

199-240

225

1262

eRib5035

0.5m x 3m

1.75m

2

187-224

262

1263

eRib5004

0.5m x 3.5m

2m

2

154-183

300

1264

eRib5045

0.5m x 4m

2.25m

2

146-172

337

1265

eRib5005

0.5m x 4.5m

2.5m

2

131-153

375

1266

eRib5055

0.5m x 5.5m

2.75m

2

130-151

412

1267

eRib5006

0.5m x 6m

3m

2

107-123

450

Summary of Contents for eRibbon

Page 1: ...eRibbon Installation Manual www electricunderfloorheating co uk Before you begin installing read through these instructions carefully and check that you have all the components required...

Page 2: ...f any heat conductive building part such as cold water pipes Install mats within 5cm of one another 10cm of any wall or 15cm of a fireplace or hot water pipe Connect any other electrical appliance on...

Page 3: ...cal consumer unit Confirm your thermostat is suitable to switch the appropriate electrical load e g 15A thermostat 230V is suitable to switch up to 22m of eRibbon If you are required to switch greater...

Page 4: ...ady for the eFoam insulation All loose particles should be removed and the floor thoroughly cleaned and treated with any proprietary sealants as normally required Step 3 Positionandcuttheefoamtofityou...

Page 5: ...secured with the single sided adhesive tape the floor sensor is used to measure the maximum temperature beneath the floor Step 6 Unfold the eRibbon with the fibreglass net facing up lay the eRibbons...

Page 6: ...mats as much as possible and the smaller mats only as gap fillers Please find below a list of the available mat sizes complete with the resistances for your reference whilst installing the eRibbon Pr...

Page 7: ...uctor off the cold tails and earth The meter should record a high resistance value e g above 100 Meg ohms Floor Construction Examples The eRibbon allows direct installation of timber laminate parquet...

Page 8: ...lpdesk 08714 74 08 18 Contact the eLine Helpdesk with any questions on 08714 74 08 18 eRibbon Edison House Unit 7 Edison Close Ransomes Europark Ipswich Suffolk IP3 9GU United Kingdom Copyright Elemen...

Reviews: