background image

ASSEMBLY INSTRUCTIONS

5

Using the Quick Connect Socket

Pull back the sleeve on the quick disconnect socket and insert the unattached end

of the gas hose into the socket. Release the sleeve and continue pushing the hose

into the socket until the sleeve snaps into the locked position. After making all

connections, perform a leak test as described on page 12 of this manual.

11 / 20

Summary of Contents for OFS006NG

Page 1: ...sonal injury or loss of life Installation and service must be performed by a qualified installer service agency or gas supplier Improper Installation adjustment alteration service or maintenance can c...

Page 2: ...icals known to be State of California to cause cancer birth defects and reproductive harm Wash your hands after handing this product Handing the brass material on this product exposes you to lead a ch...

Page 3: ...unit to combustible materials 72 182 9cm from the top 48 121 9 cm from all sides and back Do not locate this fire table under any overhead enclosure Always use this outdoor fire table on a hard level...

Page 4: ...under water DO NOT wear flammable or loose clothing when operating this outdoor fire table DO NOT use in windy conditions Keep all electrical cords away from a hot outdoor fire table Certain areas of...

Page 5: ...skin Natural gasisextremelyflammableandhazardousifhandledimproperly Chemicals known to the state of California to cause cancer birth defects or other reproductiveharm arecreated by thecombustion ofna...

Page 6: ...nual shut off valve at the gas supply WARNING During any high pressure testing of the gas supply piping system at test pressures in excess of psi 3 5 kPa the appliance and its individual shut off valv...

Page 7: ...7 20 PARTS LIST 3 4 1 Fire Table 1 2 Natural Gas Hose and Quick Disconnect 1 3 Lava Rock 1 4 Battery 1 2 1...

Page 8: ...not included 2 Place lava rock by hand DO NOT dump bag out in to the tray to avoid clogging the burner with dust Position the lava rock 13 2 lbs 6 kgs to a level about 1 above the t op of the burner...

Page 9: ...S 3 Connecting your Fire Table to the Natural Gas Source A professionally installed shut off valve between the supply piping and the socket is recommended by the National Fuel Gas Code Socket connecti...

Page 10: ...pple with gas resistant pipe compound or approved Teflon PTFE tape Screw socket onto gas supply pipe house gas source as shown to the right and wrench tighten The quick disconnect socket should never...

Page 11: ...disconnect socket and insert the unattached end of the gas hose into the socket Release the sleeve and continue pushing the hose into the socket until the sleeve snaps into the locked position After...

Page 12: ...empts disconnect natural gas source and contact Elementi at 800 678 7294 for assistance If no bubbles appear after one minute turn source OFF wipe away solution and proceed Check for leaks at these lo...

Page 13: ...Lighter 1 Prior to lighting use a shovel to move lava rocks for access to the burner 2 Wearing heat resistant gloves position the burning long match or burning butane lighter near the side of the bur...

Page 14: ...2 For finger prints or smears use 3M Stainless Steel Cleaner and Polish Arcal 20 Lac O Nu LuminWash O Cedar Cream Polish or Stainless Shine this will provide a barrier file to minimize fingerprints 3...

Page 15: ...orrectly connected Both electrode wires must be fully inserted into the igniter box 2 Make sure that the pilot housing is unobstructed Clear any debris on top of the pilot housing and make sure there...

Page 16: ...should be pointed straight to the thermocouple The thermocouple should be positioned 5mm 0 196 away from the burner tube 16 20 Thermocouple Wire Valve Wire should be in line with valve Valve Igniter B...

Page 17: ...Igniter Pin Problem Burner will not light with match Possible Cause 1 No Gas Flow Check if the LP gas tank is empty If empty replace and refill If the propane tank is not empty refer to Problem Sudden...

Page 18: ...Call your local gas company Possible Cause 3 Excess fl ow valve tripped Refer to Problem Sudden drop in gas flow 5mm 0 196 Burner Ports Problem Sudden drop in gas flow or a reduced flame height Possib...

Page 19: ...lines must be installed by a licensed gas fitter Damage caused by shipping staining and abuse are not covered under this warranty Dings dents and scratches fading and natural weathering are not covere...

Page 20: ...Ocean Rock USA LLC 1300 W 9th St Upland CA 91786 www elementifire com info elementifire com Tel 800 678 7294 ELEMENTI THE ART OF FIRE...

Reviews: