54
Element4 Gas Fireplaces Rev# 07022020
European
Home
.com
APPENDIX TWO
FUNCTION
POSSIBLE CAUSE
REMEDY
(continued)
C.
Spark will occur
each second.
Ignition components not operating
properly.
Check connection between ignition cable
and ignition electrode.
Check ignition electrode spark gap.
Check ignition electrode.
Check ignition cable for damage.
Increase distance between ignition cable
and all metal parts.
No
Ignition sequence stops, no pilot flame.
No reaction to transmitter command.
Reset system, see the installation manual
or the label on the receiver.
Do not coil the ignition cable.
Shorten the ignition cable, if possible.
No
Ignition sequence stops, no pilot flame.
Transmitter command is possible.
Test the batteries, replace if necessary.
Quality 1.5V AA alkaline recommended.
No
Yes
Ignition sequence stops after one spark Remove ground bolt (T20 Torx) and clean
ground lug.
No
Short between interrupter block and TC-
cable.
Check connection to interrupter block.
Electronic measuring amplifier defective.
Replace the receiver.
E.
Sparking stops after
pilot is lit.
No
Yes
TC- and SW-cable reversed.
Check cable connection between receiver
and interrupter block.
Magnet unit not operating properly.
Replace gas valve.
Short between interrupter and SW cable.
Check interrupter block connection.
No gas (magnet unit drops after 30 second
audible count.)
Check gas supply.
Spark not lighting the pilot.
Check spark is crossing the pilot orifice.
Cracked ignitor rod (spark heard but not
seen)
Ensure that ignitor rod does not move
within ceramic shield. Check that ceramic
shield or ignition wire is not defective.
D.
Pilot lit.
No
Yes