53
MAINTENANCE
Element4 Gas Fireplaces
European
Home
.com
THERMOCOUPLE MAINTENANCE
The Element4 fireplaces have two thermocouples; one next to
the pilot and one opposite the pilot side of the main burner. The
completeness and operation of both must be checked. A qualified
installer must confirm that both thermocouples are in place and
not damaged. While checking the thermocouple, please ensure
that the ignitor rod is not cracked as well.
VENT MAINTENANCE
The following venting system inspection by a qualified service
technician is recommended every six months:
1. Inspect for excessive condensation, e.g. water droplets
forming in the inner lining and subsequently dripping out of
the joints. This can cause corrosion in the system.
2. Check for corrosion in areas exposed to the elements.
Where rust spots or holes have appeared, these must be
immediately replaced.
3. Ensure that there is no foreign material in the vents. Survey
by removing the cap and shining a light down the vent.
4. Check all joints and pipes to make sure that nothing has
been disturbed or loosened.
The orifice for the burners is shown below. The
NG
orifices are marked 650,
LP
orifices are marked 220.
In order to convert from Natural Gas (NG) to Propane (LP) an LP Conversion Kit will be needed. This kit will include the required
orifices and an installation guide on how to complete the conversion. This conversion can only be completed by a certified
installer or gas technician. The orifice for the burners is shown below. The
NG
orifices are marked 650,
LP
orifices are marked 220.
E4-SA-LPCK-Double Burner
LP Conversion Kit
REPL-E4-GS-1T-01
Replacement Primary Thermocouple
REPL-E4-GS-2TC-01
Replacement 2nd Thermocouple
REPL-E4-GS-CMESAVE-01
Replacement Receiver
REPL-E4-GS-RCESAVE-01
Replacement Remote Control
REPLACEMENT PARTS
PROPANE (LP) CONVERSION KIT