background image

13

SPECIFICATIONS and DIMENSIONS

Element4 Gas Fireplaces Rev #05112020

                                                                                                                                                   

European

Home

.com

PARTS OF THE FIREPLACE

The various parts of the Trisore 95 MKII GSB fireplace are shown below. The Bidore and Modore versions are similar.

Table of Fireplace Parts

1

Outer Frame Face- surrounds the glass panels, limits the non-combustible wall board and allows air in.

2

Inner Glass Panel

3

Support Feet - four adjustable feet allow the fireplace to be levelled

4

Hearth Panel - supports various fire media

5

Primary Burner - produces the main flame

6

Pilot Burner - the part of the safety circuit which lights the Primary Burner

7

2

nd

 Thermocouple - the part of the safety circuit which monitors the Primary Burner

8

Finish Trim - hides the Inner Glass Clamps

9

Inner Glass Clamps - holds the Inner Glass Panels in place

10

Vent Collar - accepts the 5” x 8” venting adapter (included)

11

Relief Door - part of the safety system. Do NOT block the operation of the relief doors.

12

Pilot Assembly

77

66

88

44

55

10

10

22

99

99

99

12

12

33

33

11

11

33

33

11

11

11

11

11

Figure 10: Fireplace as seen 

from below

88

Figure 9

Figure 11

Summary of Contents for Lucius 100 GSB

Page 1: ... building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or...

Page 2: ...ting 19 Configuration 19 Venting Charts 22 Termination Clearances 23 Enclosing the Fireplace 25 Non Combustible Materials List 25 Cold Climate Installation 31 Locating the Controls 31 Wall Access Door Locating and Mounting 31 Installing the Fire Media 33 Operating the Fireplace 35 Maintenance 42 Glass 42 Burner 44 Pilot 44 Thermocouple 45 Venting 45 Replacement Parts 46 Warranty 47 Massachusetts C...

Page 3: ...n we STRONGLY RECOMMEND that you install in front of the fireplace a fire screen or to protect young toddlers a hearth gate HOT SURFACES Be aware that although safe some combustible materials and finishes even though installed at listed clearances may over time discolor warp or show cracks Convective heat will exit the unit and travel up the wall surface if not impeded Protruding mantels and proje...

Page 4: ... or substitute any part of this appliance WARNING Glass Handling The glass must only be removed by a qualified person Gloves should be worn when removing the glass WARNING Electrical Grounding These direct vent appliances must be electrically grounded in accordance with the local codes or in the absence of local codes with National Electric code ANSI NFPA 70 or the Canadian Electric Code CSA C22 1...

Page 5: ...anufacturer NO SUBSTITUTE panels shall be used DO NOT USE abrasive cleaners on the panels DO NOT ATTEMPT to clean the glass panels when they are hot TURN OFF the gas before servicing the appliance It is recommended that a qualified service technician perform an appliance check up service once a year Any safety screen or guard removed for servicing MUST BE REPLACED before operating this appliance T...

Page 6: ...d BEFORE the first light The amount of square inches needed for the opening varies from model to model F ENCLOSING THE FIREPLACE ONLY a tested and approved non combustible wallboard that is specified in the manual may be used when enclosing the fireplace F FRAMING The dimensions are different between metal and wood framing Know which material you are using and know the framing requirements F VENTI...

Page 7: ... room air which enters through the Room Air Inlets As this warm air cools it falls toward the floor where it s drawn into the inlet and the cycle repeats The Room Air Inlets are part of the fireplace and cannot be blocked or adjusted The amount of square area required for your Convection Air Outlet s is determined by the fireplace model and is listed in the installation manual As seen in the illus...

Page 8: ...stallation Manual is included with your fireplace and is available at www europeanhome com Please call us if you have any questions or are uncertain about any aspect of your installation Let Us Help European Home and its retail partners are here to assist you with your unique fireplace design Let us help you today Element4 Gas Fireplaces EuropeanHome com 2 Contact your local dealer if you have any...

Page 9: ...n the two layers of viewing glass thus providing warm air to the room For proper operation the Glass Safety Barrier GSB needs two openings an air inlet into which room air is drawn and an air outlet which allows warm air to escape The inlet for room air in and the outlet for warm air out are built into the walls which enclose the fireplace and are part of your design See the ENCLOSING the FIREPLAC...

Page 10: ...ing label must not be removed from the fireplace A DWG DXF file is available for download at www europeanhome com for dimensions not shown CAD FILES Model Tenore 100 GSB Lucius 100 GSB Gas Natural Gas Propane Input Maximum Btu hr 59 000 46 000 Input Minimum Btu hr 22 000 20 500 Maximum Supply Pressure in w c 7 11 kpa 1 74 2 74 Minimum Supply Pressure in w c 4 8 kpa 1 0 2 0 Manifold Pressure Maximu...

Page 11: ...rent 500 mA Size 3 1 H x 2 W x 1 7 D Output Cord Length 6 Feet Agency Approvals UL CSA ELECTRICAL SPECIFICATIONS Input Voltage 115 120 VAC 50 60 Hz Maximum Rating 10A 104 F Cord Length 6 Feet Agency Approvals UL Fan Set A Fan Set B L2 L1 Snap Switch Speed Control GND Fan Set Electrical Schematic Fan Set C Fan Set D Fan Set E Figure 5 AC Adapter Connection Figure 4 Figure 6 Figure 7 ...

Page 12: ...0 GSB Planning Dimensions 8 2017 This information is for reference only Please consult the Installation Manual for all details prior to making any design decisions Conversions from millimeters are rounded to the nearest fraction A DWG file is available at www europeanhome com PDE4L100GSB 170807 Letter Inches Millimeters A 43 5 16 1100 B 16 13 16 427 C 9 1 4 235 D 57 5 8 1464 E 33 7 8 860 G 32 813 ...

Page 13: ... Panel supports various fire media 5 Primary Burner produces the main flame 6 Pilot Burner the part of the safety circuit which lights the Primary Burner 7 2nd Thermocouple the part of the safety circuit which monitors the Primary Burner 8 Finish Trim hides the Inner Glass Clamps 9 Inner Glass Clamps holds the Inner Glass Panels in place 10 Vent Collar accepts the 5 x 8 venting adapter included 11...

Page 14: ...ning must be cut through the platform top The lineset can be routed through this opening Room air must be allowed to flow through the Wall Access Door and the air Inlet openings then through this platform opening A linear cutout shape shown crosshatched below will perform best The feet on the appliance are designed to sit on a flat platform howevertheappliancemustnotbeinstalledonanycombustible mat...

Page 15: ...ce to the outer faces of the appliance outer frame face However they must not cover or prevent the removal of the glass panels or other fireplace parts The appliance must not be installed on any combustible material other than wood These clearances are the same for ALL Element 4 Fireplaces regardless of model We recommend that the fireplace be set into its final location before building the enclos...

Page 16: ...cordance with the chart below Mantels made of non combustible material are allowed inside these dimensions but they will be subjected to elevated temperatures and may become too hot to touch A typical completed installation with mantel is shown in the diagram below on the right A B B 2 50 C SECTION A A 36 900 36 900 36 900 SECTION B B COMBUSTIBLE MATERIALS NOT PERMITTED IN FRONT OF GLASS 2 50 11 2...

Page 17: ... of the Air Outlet must be no more than 1 25 mm down from the chase ceiling The minimum distance from the bottom of the appliance to the room ceiling is 72 1830 mm Minimum Required Air Opening Sizes Air Inlet Air Outlet Model Square Inches Square Centimeters Square Inches Square Centimeters Tenore 100 GSB Lucius 100I GSB 145 936 145 936 Minimum Distances A Room ceiling to appliance bottom 72 1830 ...

Page 18: ...Maximum Supply Pressure as shown in the Specifications and Dimensions section of this manual The gas supply line must be properly connected and bled by a certified gasfitter or plumber The appliance and its main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa The appliance must be isolated fr...

Page 19: ... 25 mm must be maintained between combustible materials and any other vent pipe surface The horizontal parts of the venting must be pitched up away from the fireplace For every 12 305 mm of horizontal run the venting must rise 1 4 6 5 mm toward the termination The venting must never run downward unless with the use of a power vent Whenever venting passes through a wall an approved heat shield or w...

Page 20: ...al Pipe Section T Vertical Pipe Section S CALCULATING THE TOTAL VERTICAL SECTION TVS Calculate the Total Vertical Section by adding up all vertical upward sections in your vent design CALCULATING THE TOTAL HORIZONTAL SECTION THS Calculate the Total Horizontal Section by adding up all horizontal sections in your vent design R CONFIGURATION R R N N N N N N Q T T T S S S S S Figure 22 Figure 23 Figur...

Page 21: ...0 1m to your THS for a 90 Type Q elbow you must add 80 2m to your THS for each 45 Type Q elbow you must add 40 1m to your THS Once you have found your total vertical section TVS and your total horizontal section THS plot the intersection of these two numbers on the appropriate chart below The intersecting block will have one of three entries 0 35 or X If your TVS and THS intersect at a block with ...

Page 22: ...n Allowed Venting and Restrictor Requirements 32 10 10 m 35 35 35 35 35 0 0 29 7 9 m 35 35 35 35 35 0 0 26 3 8 m 35 35 35 35 35 0 0 23 7 m 35 35 35 35 35 0 0 19 8 6 m 35 35 35 35 35 0 0 16 5 5 m 35 35 35 35 35 0 0 13 2 4 m 35 35 35 35 35 0 0 11 6 3 5 m 35 35 35 35 35 0 0 9 10 3 m 0 0 0 0 0 0 0 8 3 2 5 m 0 0 0 0 0 0 x 6 7 2 m 0 0 0 0 0 x x 5 1 5 m 0 0 0 0 x x x 3 4 1 m 0 0 0 x x x x 1 8 0 5 m x 0 x...

Page 23: ...23 VENTING Element4 Gas Fireplaces Rev 05112020 EuropeanHome com HORIZONTAL VENT TERMINATION CLEARANCES AND REQUIREMENTS CLEARANCES Figure 32 Figure 33 ...

Page 24: ...ne and do not supersede local codes in any way Install venting according to local codes these instructions the current National Fuel Gas Code ANSI Z223 1 in the USA or the current standard of CAN CSA B149 1 in Canada VERTICAL TERMINATION CLEARANCES AND REQUIREMENTS Figure 36 Multiple Termination Clearance A second termination may be no closer than 12 305 mm CLEARANCES Figure 34 ...

Page 25: ...re non combustible The table below Figure __ shows a list of materials which are reported by their manufacturers to be non combustible in accordance with the ASTM E136 standard AND approved for use around fireplaces Skamol Skamotec 225 and the Promat PROMAFOUR system are preferred products for enclosing fireplaces Product Thickness Skamol Skamotec 225 Fireplace Building Board 11 2 38 mm Promat PRO...

Page 26: ...50 mm air gap between the wall shield and the fireplace MUST be maintained A 2 50 mm air gap between the wall shield and the fireplace MUST be maintained BUILDING the ENCLOSURE A safe installation of your Element4 fireplace requires that four things be clearly understood Most important these fireplaces are NOT zero clearance fireplaces Unlike zero clearance fireplaces there is not a metal box arou...

Page 27: ... MAINTAINED Shield Over Finished Wall Shield Over Finished Wall Combustible Wall Combustible Wall Combustible Wall Combustible Wall Shield Over Finished Wall Shield Over Finished Wall 2 50 2 50 mm mm Minimum Air Minimum Air Gap MUST BE Gap MUST BE MAINTAINED MAINTAINED REDUCED CLEARANCE TO EXISTING COMBUSTIBLE WALLS Figure 38 Figure 39 Figure 40 Figure 41 ...

Page 28: ...ur choice of wall material depends largely on the intended finish If a painted finish is desired then a wall at least 1 2 12 mm thick will suffice Minimum Wall Thickness 1 2 12 mm Product Thickness Skamol Skamotec 225 Fireplace Building Board 11 2 38 mm Promat PROMAFOUR System 1 2 12 mm James Hardie Building Products HardieBacker 500 1 2 Cement Board 1 2 12 mm James Hardie Building Products Hardie...

Page 29: ...imeters Lucius 100 GSB 145 936 145 936 7 175 7 175 mm minimum mm minimum distance between viewable distance between viewable fireplace opening and top fireplace opening and top of air inlets MUST BE MAINTAINED of air inlets MUST BE MAINTAINED to allow free flow of air to allow free flow of air Air outlets installed in a reveal hidden Air outlets installed in wall visible Figure 45 Figure 47 Figure...

Page 30: ...e framing ONLY must be at least 2 50 mm away from any part of the fireplace The entire weight of the non combustible walls must be borne by a structure other than the fireplace Tenore 100 GSB shown The Lucius 100 GSB model have the same requirement Use the adjustable feet to ensure that the fireplace is level prior to enclosing it Do NOT lift the fireplace by the face frame but by the bottom of th...

Page 31: ...ontrol the gas valve and the power supply The remote control is the device by which you operate the fireplace The receiver and the gas control are at one end of a line set which is connected to the firebox near the center As shipped the line set is wrapped together and fixed to the fireplace Remove all wraps and ties prior to installation The Wall Access Door is provided with your fireplace When l...

Page 32: ...e for at least thirty 30 seconds 2 Start the fireplace with the hearth panel in place and with all of the glass panels fixed correctly in place Ensure that the main burner flames engulf the 2nd thermocouple and the fireplace stays lit for at least 1 full minute If the system turns itself off after 20 seconds install the required media next section and return here Installing the fire media will hel...

Page 33: ...e bag of chips evenly on the hearth panel and burners Ensure that the area inside the pilot shield and the area around the 2nd thermocouple remains clear of media With the embers scattered across the burner and hearth panel lay the logs in the following sequence A A A A B B B B C C C C D D D D E E E E F F F F G G G G H H H H H H LSE 45 II Log Set Contents one small bag of ash use optional two pine...

Page 34: ... Ensure that the hearth panel is level and sitting firmly on the base of the fire box The pilot flame must be visible through the hearth panel and the pilot shield Evenly scatter the contents of the bag of stones glass over the top of the hearth panel and burner Ensure that none of the stones glass enters the pilot area or restricts the operation of the 2nd thermocouple The arrangement is now comp...

Page 35: ...necessary pair the remote and receiver see below 8 Follow USING THE REMOTE CONTROL ELECTRONIC IGNITION SEQUENCE to setup and use remote PAIRING THE REMOTE AND RECEIVER System Reset 1 Press and hold the receiver reset button using a small long tool until you hear the second of two beeps After the second beep release the reset button 2 Press and hold the button on the remote until you hear the secon...

Page 36: ...36 OPERATING the FIREPLACE Element4 Gas Fireplaces Rev 05112020 EuropeanHome com 1 OPERATING the FIREPLACE Element4 Gas Fireplaces EuropeanHome com Figure 60 Figure 61 Figure 63 Figure 62 ...

Page 37: ...TING the FIREPLACE Element4 Gas Fireplaces Rev 05112020 EuropeanHome com 2 OPERATING the FIREPLACE Element4 Gas Fireplaces EuropeanHome com Figure 64 Figure 65 Figure 66 Figure 67 Figure 68 Figure 69 Figure 70 ...

Page 38: ...IREPLACE Element4 Gas Fireplaces Rev 05112020 EuropeanHome com 3 OPERATING the FIREPLACE Element4 Gas Fireplaces EuropeanHome com Figure 71 Figure 72 Figure 73 Figure 74 Figure 75 Figure 76 Figure 77 Figure 78 Figure 79 ...

Page 39: ...39 OPERATING the FIREPLACE Element4 Gas Fireplaces Rev 05112020 EuropeanHome com 4 OPERATING the FIREPLACE Element4 Gas Fireplaces EuropeanHome com Figure 80 Figure 81 Figure 82 ...

Page 40: ...nstall handset batteries All icons are displayed and flashing 2 To activate a function press the relevant button and hold for 10 se conds 3 The function icon will continue to flash until activation is complete Ac tivation is complete when the function icon is displayed The following Functions can be Deactivated Activated CHILD PROOF To activate press and buttons simultaneously displayed and the ha...

Page 41: ...pear as the glass warms During this first fire examine the flame for appearance and quality Examine the burner media for sooting The flames should look like those shown below After this burn off period turn off the fireplace and let it cool completely to room temperature and clean both sides of the glass and the interior panels as described in the MAINTENANCE section Since it is a metal fireplace ...

Page 42: ... top and bottom channels Step 2 For each Outer Glass Panel attach the suction cup to the center of the glass and lift the glass up into the clearance notch When the glass panel is raised into the clearance notch there is enough clearance to swing the lower edge of the glass panel out into the room When the glass panel is outside of the frame lower the glass panel out of the clearance notch and car...

Page 43: ...ower edge of the glass in and down into the channel Step 5 For each Inner Glass Panel attach the suction cup and remove as done with the Outer Glass Panels Burning natural gas NG or propane LP in this fireplace will always result in some of the gas components being deposited on the glass Hydrogen sulfides and mercaptans which are present in the burning gas condense onto the relatively cooler glass...

Page 44: ...ufacturer Inspect the external vent cap on a regular basis to make sure that no debris plants trees or shrubs are interfering with the air flow BURNER MAINTENANCE The flames from the burner should be visually checked The flame should have a blue base and yellow tops and be candle like in appearance PILOT MAINTENANCE The pilot flame must be visually checked The pilot flame must always be present wh...

Page 45: ...n the inner lining and subsequently dripping out of the joints This can cause corrosion in the system 2 Check for corrosion in areas exposed to the elements Where rust spots or holes have appeared these must be immediately replaced 3 Ensure that there is no foreign material in the vents Survey by removing the cap and shining a light down the vent 4 Check all joints and pipes to make sure that noth...

Page 46: ...ired Part Number Each 1 Gas valve 1 E4 GS GV 01 2 Receiver Control Module 1 Befor 1 2020 E4 GS CM Wifi 03 After 1 2020 E4 GS CM Wifi 04 3 Main Burner 4 Second Burner 5 Piolot Assembly 1 E4PGS PABT 01 6 Second Thermocouple 1 E4 GS 2TC 01 7 6 Volt Adaptor 1 AC Adaptor 03 8 Wifi Box Optional 1 E4 GS Con Wifi 01 9 10 Button Remote 1 Repl E4 GS RC 10B Figure 93 Figure 95 Figure 94 1 2 3 4 5 6 8 9 7 ...

Page 47: ... your property and the replaced item becomes the property of European Home All warranty claims must be submitted through the dealer from which you purchased the product Check with your dealer in advance for any costs to you when arranging a warranty call Shipping and or delivery charges for parts are not covered by this warranty Nothing in the above shall be deemed to imply that this warranty shal...

Page 48: ...gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector observes carbon monoxide detectors and signage install...

Page 49: ...ricity Wait for 2nd thermocouple to cool down 3 5 minutes FUNCTION POSSIBLE CAUSE REMEDY Yes No A Press the ON button to start ignition sequence Beep will occur each second continued TROUBLESHOOTING FLOW CHART Receiver batteries low Test the batteries replace if necessary Quality 1 5V AA alkaline recommended Impulse magnet not operating properly Replace gas valve B Magnet unit is energized thus pr...

Page 50: ...the batteries replace if necessary Quality 1 5V AA alkaline recommended No Yes Ignition sequence stops after one spark Remove ground bolt T20 Torx and clean ground lug No Short between interrupter block and TC cable Check connection to interrupter block Electronic measuring amplifier defective Replace the receiver E Sparking stops after pilot is lit No Yes TC and SW cable reversed Check cable conn...

Page 51: ...nd tight plus 1 4 turn maximum No gas magnet unit drops after 30 second audible count Check gas supply Ignition sequence stops No reaction to transmitter command Reset system see the installation manual or the label on the receiver Do not coil the ignition cable Pilot flame under hearth panel not establishing Remove glass and hearth panel then check for proper pilot operation If pilot establishes ...

Page 52: ...Timer modes if the ambient room temperature changes the flame height will adjust automatically to maintain the set temperature and the fire will continue to function normally The valve will turn to pilot flame if the set temperature and the ambient temperature remain the same over a 6 hour period No Main burner remains lit while flames are lowered Main valve knob is turned via motor No System goes...

Page 53: ...rsion instructions Flow of fresh air and or exhaust is blocked Ensure that vent configuration is within the vent chart requirements Check termination for blockage and or appropriate type No J Flames become thin blue wispy then go out Yes Exhaust is contaminating the fresh air Inspect venting for damage and or incorrect installation Flow of fresh air and or exhaust is blocked Ensure that vent confi...

Page 54: ...lve to Pilot close contact 3 In each case the contacts need to be closed for 12 seconds to turn the motor from one end stop to the other end stop To set the valve to the Off position close contacts 1 2 and 3 simultaneously for 1 second Modes of Operation Mode 1 the external source provides ON and OFF operation only The remote control provides all other functions Note Even if the fire is switched o...

Page 55: ...d No right recipient F15 Contact service 5 sec beep No reaction from the fireplace and no ignition 2nd thermocouple not connected Wiring 2nd thermocouple F16 Hand transmitter out of reach No temperature in the app Hand remote control out of reach for more than 1 5 hours Electrical fault F17 Contact service No ignition No reaction from the fireplace Voltage above 7 5 volts AC adapter defective F19 ...

Page 56: ... time a start attempt within 5 minutes No gas Air in the pipe No spark F09 F09 4 sec No reaction from the fireplace No electronic control Retry startup F40 Battery symbol Contact service Continu Battery voltage in the hand transmitter too low Replace batteries 2x 1 5 V AAA F46 F46 4 sec No reaction from the fireplace Interrupted responses No electronic control No or bad connection between the rece...

Page 57: ... position You prevent long distances from occurring Many people put the router in the meter cupboard because that is where the internet comes in at many households A bad choice For a powerful WiFi signal the router needs as much space as possible Therefore do not place the device near a wall or on the ground Some routers have multiple antennas that you can target Try to spread these antennas so th...

Page 58: ...ing to LP 45 Installing the Gas Line 18 Pressures 10 K KEY INSTALLATION POINTS 6 L LISTING LABEL 10 LP Propane Conversion 45 M MAINTENANCE Burner 44 Glass 42 Pilot 44 Thermocouples 45 Venting 45 MANTELS 16 N NON COMBUSTIBLE MATERIALS Minimum Clearances 14 O OPERATING THE FIREPLACE Test Fire 32 Using the Remote Control 45 P PARTS OF THE FIREPLACE 13 S SAFETY INFORMATION 3 SMART HOME SYSTEM Appendix...

Page 59: ...59 Element4 Gas Fireplaces Rev 05112020 EuropeanHome com NOTES ...

Page 60: ...places Rev 05112020 EuropeanHome com IGE45IIG 180328 EUROPEAN HOME a division of Europa Ja Inc 30 Log Bridge Road Building 300 Suite 303 Middleton MA 01949 www europeanhome com Imported and distributed in North America by ...