38
1 2
ON
AM
PM
OFF
handset one-Button operation
(Default Setting)
▪ Press button until two short beeps
and a blinking series of lines confirms
the start sequence has begun; release
button.
▪ Main gas flows once pilot ignition is
confirmed.
▪ Handset automatically goes into Man-
ual Mode after main burner ignition.
NOTICE
Change from one-button to two-button ignition operation by
pressing and holding button for 10 sec. immediately after
installing batteries.
is displayed and
is flashing. When
change is complete
will change to .
1 2
ON
AM
PM
OFF
handset Two-Button operation
▪ Press and button simultaneously
until two short beeps and a blinking
series of lines confirms the start se-
quence has begun; release buttons.
▪ Main gas flows once pilot ignition is
confirmed.
▪ Handset automatically goes into Man-
ual Mode after main burner ignition.
Change from two-button to one-button ignition operation by
pressing and holding button for 10 sec. immediately after
installing batteries.
is displayed and is flashing. When
change is complete will change to
.
NOTICE
WARNING
If the pilot does not stay lit after several tries, turn the main valve
knob to
oFF
and follow the instructions “TURN OFF GAS TO
APPLIANCE” (page 30).
STaNDBy moDE (pILoT FLamE)
handset
▪ Press and hold button to set appliance to pilot flame.
To TURN oFF FIRE
1 2
ON
AM
PM
OFF
handset
▪ Press button to turn OFF.
NoTE:
There is a 5 sec delay before
the next ignition is possible.
FLamE hEIghT aDjUSTmENT
1 2
ON
AM
PM
OFF
handset
▪ To increase flame height press and
hold button.
▪ To decrease flame height or to set ap-
pliance to pilot flame, press and hold
button.
DESIgNaTED LoW FIRE and hIgh FIRE
NoTE:
Backlight must be on for high fire and low fire double-click
operation.
AM
▪ To go to low fire, double-click but-
ton. is displayed.
NoTE:
Flame goes to high fire first be-
fore going to low fire.
AM
▪ To go to high fire, double-click but-
ton. is displayed.
WARNING
If the appliance will not operate, follow the instructions “TURN
OFF GAS TO APPLIANCE” (page 30).
coUNTDoWN TImER
1 2
ON
AM
PM
OFF
ON/SETTING:
1. Press and hold button until dis-
played, and
hour
flashes.
2. To select hour press or button.
3. To confirm press button.
minutes
flash.
4. To select minutes press or button.
5. To confirm press button or wait.
OFF:
Press button, and countdown time
disappear.
NoTE:
At end of countdown time period, the fire turns off. The
Countdown Timer only works in Manual, Thermostatic,
and Eco Modes. Maximum countdown time is 9 hours
and 50 minutes.