2 9
Appendix F
I N S T A L L A T I O N M A N U A L |
Gas type »
NATURAL GAS
LPG
Country of use »
AT,BG,CH
DK,ES,FI
GB,GR,HR
IE,IT,LT
LV,NO,PT
RO,SE,SI
SK,TR
DE,LU
PL
BE,FR
DE
NL
BG,DK,EE
FI,GB,GR
HU,HR,IT
LY,MT,NL
NO,RO,SE
SI,SK,TR
CZ,LT
NL,SK
AT,CH
CZ,DE
AT,BE,CH
CZ,DE,ES
FR,GB,IE
IT,NL,PT
SK,TR
Gas Category »
I2
H
I2
E
I2
E+
I2ELL
I2
L
/ I2
EK
I3
B/P
I3
p
I3
P
I3+
Unit
G20
G20
G20/G25
G20/G25
G25/G25,3 G30/G31
G30
G31
G30/G31
Supply pressure
mbar
20
20
20 / 25
20
25
30
50
28 - 30/37
30
Burner pressure
mbar
12,3
12,3
12,3 / 15,2
12,3
15,2
28,5
28,5
28,5
28,5
Gross input
kW
13
13
13 / 12
13,0
12,0
8,5
8,5
8,5
8,5
Net input
kW
11,7
11,7
11,7 / 10,8
11,7
10,8
7,7
7,7
7,7
7,7
max. Heat output
kW
9,7
9,7
9,7 / 9
9,7
9
6,4
6,4
6,4
6,4
min. Heat output
kW
3,2
3,2
3,2 / 3
3,2
3
2,1
2,1
2,1
2,1
(Max.) Gas usage
m
3
/hr
1,24
1,24
1,24 / 1,33
1,24
1,33
0,24
0,24
0,24
0,24
kg/hr
0,88
0,88
0,88 / 0,98 0,88 / 0,98
0,98
0,44
0,61
0,44
0,44
NOx
mg/kWh
input
<100
<100
Pilot
446,0330,14
446,0330,07
Burnerinjection
1200
240
Type of flue
C11 / C31 / C91
Additional electricity use
•
At rated heat output
el
max
9
-5
kW
•
With minimal heat emission
el
min
9
-5
kW
•
In standby mode
el
sb
9
-5
kW
Power requirement for the permanent pilot light
Power requirement for the permanent pilot
light (requirements applicable)
P
pilot
Does not
apply
Efficiency (NCV)
•
Efficiency at rated heat output
η
th, nom
83 %
•
Efficiency at min. heat output (indicative)
η
th, min
54 %
Type of heat release / control room temperature (Select one)
•
With electronic control of the room temperature plus week switch
Other control options
•
Control of the room temperature with presence detection
•
Control the room temperature with open window detection
•
With the option of remote control
•
With adaptive control of the start
•
With limitation of the operating time
Glass size
•
Front
450 x931 x 4 mm
•
Side
450 x 242 x 4 mm
F
TECHNICAL DATA
The dataplate specifies for which type of gas, gas pressure and for which
country this appliance is intended. The nameplate is attached to a chain.
It must remain attached to the chain.
Note:
Check whether the appliance is suitable for the gas type and gas
pressure on site.