Problem

Possible Cause

Solution

G

The pilot light goes 

on but goes out 

immediately when 

the main burner 

switches on

1

Insufficient voltage across the thermocouple or 

too much resistance in the thermocouple circuit

Place the measuring pins of the multimeter on the ground and 

black cable of the breaker. This value must be at least 4.5 mV.

Tip:

 For this action a video is available on our youtube channel

2

Gas pressure loss may cause the pilot flame to be 

too small

Check and measure the pre-pressure via test point A (See 

Figure 

A.D

)

Tip 1:

 Measure the pre-pressure load and unloaded

Tip 2: 

For this action a video is available on our youtube channel

3 Thermocouple defect 

Replace thermocouple

Tip:

 Always use a new pressure piece when a thermocouple is 

replaced

4 Thermocouple is incorrectly positioned

Check the position of the second thermocouple. 
(See 

Figure A.G

)

H

Check the position 

of the second 

thermocouple. (See 

Figure A-7)

1 Decoration material blocks 2nd thermocouple

Leave the space around and at the 2nd thermocouple free of 
decorative material. (See 

Figure A.H

)

2

Burner grille does not fit well with the 2nd 

thermocouple

Position burner grate

3

Airflow in the burner chamber causes a restless 

fire image

Check drain configuration

Fit a flue gas limiter

I

Receiver gives 3 

short beeps after 

each command:

1 Batteries in the receiver are empty

Replace the batteries4x 1.5V AA 

J

Pilot is on but the 

main burner does 

not start working:

1 Gas valve is on manual

Set Knob A must be in the ON position (see 

Figure A.1

). 

K

Double burner does 

not work:

1 RESET the receiver

Briefly press the RESET button and the receiver sounds 1 beep 

(See 

Figure A.J

)

2 Wiring loose on the receiver

Click the plug in the AUX position on the receiver.
(See 

Figure A.K

)

3

Solenoid valve does not switch

Replace the solenoid valve.

Tip: Only connect a new valve to the receiver first

4 Remote defective.

Check if the AUX symbol is on the display when you press the 
PLUS PLUS key on the remote. (See 

Figure A.L

)

L

No response from 

the receiver when 

the fireplace 

is started via 

smartphone or 

tablet. 

Disconnect the Wi-Fi box from the receiver

Click the plug from the SI connection on the receiver (See 

Figure 

A.M

)

Tip: 

Reset the home router

If the fireplace now functions normally, check the Wi-Fi settings

M

Hearth does 

not respond via 

Domotica system

Disconnect the cabling on the Domotica system and start the fire 

with the hand transmitter

When the fireplace now reacts normally, the problem is in the 

Domotics

Summary of Contents for BIDORE

Page 1: ...INSTALLATI O N MA NUAL INSTALLATI O N MA NUAL Please leave these instructions behind with the device M O D O R E B I D O R E T R I S O R E 1 0 0...

Page 2: ...INSTALLATION MANUAL i Do not use this product as a primary heat source...

Page 3: ...ION 8 6 1 FIRE SAFETY DEVICE SET UP 8 6 1 1 PROTECTION OF WALL AND CEILING 8 6 2 ASSEMBLY REGULATIONS 8 6 2 1 GENERAL ASSEMBLY REGULATIONS 8 6 2 2 ASSEMBLY REGULATIONS FOR NON FLAMMABLE MATERIALS 8 6...

Page 4: ...OR MALFUNCTION 19 A B NECESSARY TOOLS 23 B ERRORS CODES PROCONTROL APP 24 B A MESSAGES SHOWN IN APP 24 B B MESSAGES SHOWN IN REMOTE 25 C FAULTS AND ERROR CODES IN THE REMOTE 26 C A F41 ERROR 26 C B RO...

Page 5: ...nted to the device Make sure it is accessible at all times This device may not be used a primary heat source This device is designed to be used with natural gas or LPG The device can only be used with...

Page 6: ...sembly error or material defect Element4 will provide a free replacement part to the installer without compensation for disassembly or montage 5 In case the installer is not able to fix the problem hi...

Page 7: ...ON 1 2 OFF Figure 3 1 Remote and ignition sign Figure 3 2 Gas Block Figure 3 3 Top and side view of the Receiver 4 2 IGNITING THE PILOT LIGHT Check that the control knob A is in the ON position Figur...

Page 8: ...e in the near vicinity of the device Position the gas connection such that it is always accessible for service purposes The gas block and receiver are under the combustion chamber in the deivce so tha...

Page 9: ...objects e g built in furniture or wooden panels are mountedonthesideofthewallthatisturnedawayfromthefireplace For these types of installations please refer to CHAPTER 6 2 3 CHAPTER 6 2 3 6 2 ASSEMBLY...

Page 10: ...fireplace 200 C Table 6 1 Legenda 6 7 21 6 6 7 21 6 E d3 D F G I d1 H A2 B C d2 Figure 6 4 C31 Flue situation Flammable materials 6 7 21 6 RQ 5 1 339 0 4 81 66 27 5 6 63 0 16 216 5 1 0 0 7 56 685 1 6...

Page 11: ...enclosure ventilation opening are necessary Figure 6 5 The ventilation grills are to be placed at a minimal distance of 20cm from the ceiling and 30cm from any built in furniture from the side any fla...

Page 12: ...ee APPENDIX E APPENDIX E you search for the corresponding calculation tables Each category refers to a set of tables 1 A table for horizontal outlet 2 A table for vertical outlet 3 A table for reducti...

Page 13: ...FLUE MATERIAL Follow the following instrucions for the installation of flue materials Drill a hole of 160 mm for the wall or roof transit with a 150 mm diameter flue connection and 210 mm with a flue...

Page 14: ...erature of you device for a period of one week to ensure yourself of an optimal desired room temperature Also the device can changed between high and low flames and it features an eco setting The amou...

Page 15: ...re removed in as in step 10 1 1 Remove the ropes holding the glass See Figure 9 3 Put the section cup on the glass and make sure it is properly vaccuumed so it will not come off See Figure 9 4 Lift th...

Page 16: ...15 Chapter 9 INSTALLATION MANUAL Figure 9 2 Remove side trims Figure 9 3 Put on suction cup Figure 9 4 Remove Glass ropes Figure 9 5 Remove Windows...

Page 17: ...this is the case check the burner pressure at the inlet to the burner The instructions of changing the burner pressure and the correct pressure per gastype can be found in 9 3 2 PILOT The pilot flame...

Page 18: ...of the appliance 10 DECORATIVE CERAMIC PARTS This appliance is equipped with a ceramic fire bed with heat resistant ceramic fibers or artificial glassy silicate fibers Excessive exposure to this mate...

Page 19: ...ble plus button to switch between burners Flames and soot During this first fire examine the flame for appearance and quality Flames may appear blue at first but will turn yellow after 15 to 20 minute...

Page 20: ...turbs the reception Change the position of the antenna See Figure A B C No ignition no beep 1 Receiver defective Reset the receiver See K1 If necessary replace the receiver D No ignition receiver give...

Page 21: ...Appendix A INSTALLATION MANUAL Figure A A Bend pin Figure A B Antenna Figure A C Torx screw Figure A D Testpoint 4 5 mV 4 5 mV Figure A E Interrupter Figure A F Wiring receiver 40mm Figure A G Pilot s...

Page 22: ...ouple Position burner grate 3 Airflow in the burner chamber causes a restless fire image Check drain configuration Fit a flue gas limiter I Receiver gives 3 short beeps after each command 1 Batteries...

Page 23: ...Aux position receiver AM PM ON 1 2 OFF Figure A L Double plus button on the remote Figure A M SI port PANEL G60 ZCE 1000 MA GR MO SW 2 1 3 MODE Ignition Main Burner High Flames Pilot Extinguish Main...

Page 24: ...ed Please note If a problem is found that cannot be solved on site always contact your dealer or directly contact Element4 via our credentials which can be found on the back page of this manual 00 00...

Page 25: ...eeps for 3 sec during motor turn Low Receiver battery power supply F10 Contact Service Pilot lit Main burner fails to ignite and pilot shuts off Ignition is blocked for 2 minutes 2nd thermocouple is o...

Page 26: ...mmunication between Receiver and myfire Wi Fi Box F44 Contact Service No temperature shown in App N a not applicable displayed in App Handset not within range Low battery power in handset F49 Contact...

Page 27: ...istances from occurring Many people put the router in the meter cupboard because that is where the internet comes in at many households A bad choice For a powerful WiFi signal the router needs as much...

Page 28: ...NAL LOCATION WITH VERTICAL EXHAUST C11 Distance Exhaust 1 2 of 3 At the same roof level 6m At a different roof level 3m On a lower wall 2m On a higher sloping surface 6m Distance minimum distance requ...

Page 29: ...V 4 O O O O O V V V V 3 5 O O O O O V V V V 3 V V V V V V V V V 2 5 V V V V V V V V X 2 V V V V V V V X X 1 5 V V V V V V X X X 1 V V V V V X X X X 0 0 5 1 2 2 5 3 5 4 4 5 5 Total Horizontal Section T...

Page 30: ...urnerinjection 1200 240 Type of flue C11 C31 C91 Additional electricity use At rated heat output elmax 9 5 kW With minimal heat emission elmin 9 5 kW In standby mode elsb 9 5 kW Power requirement for...

Page 31: ...lways supplied with the fireplace The ecolabel shows which category the fireplace belongs to G A ECOLABELS The ecolabels for the different types of gas are indicated below respectively G20 G25 and G30...

Page 32: ...DRAWINGS On this page you will find the dimensional drawings of the Fireplace with some of the important dimensions that you have to take into account when installing and installing your fireplace Fi...

Page 33: ...32 Appendix H INSTALLATION MANUAL Figure H A Dimensional drawing of the Bidore 100...

Page 34: ...33 Appendix H INSTALLATION MANUAL 119 420 235 714 918 1000 280 1036 338 980 47 311 165 420 200 930 980 170 427 Figure H A Dimensional drawing of the Trisore 100...

Page 35: ...Info element4 nl www element4 nl 26 01 22 ELEMENT 4 B V Design Assembly by RELEASE DATE...

Reviews: