10
Typ Nr.
kW cos kW cos
Hz min
-1
min
-1
Hz
Mot. EN 60034-1 IP W-Kl.F
V V
A A
D-73760 Ostfildern
Germany
EN
Operating and assembly instructions HRD BOOSTED
www.elektror.com
016341 03.14/07
CONTENTS
1 MACHINE SPECIFICATIONS
2 INFORMATION ON TRANSPORTATION, HANDLING
AND STORAGE OF THE MACHINE
3 INFORMATION ON STARTING UP THE MACHINE
4 INSTRUCTIONS FOR OPERATION AND USE
5 INSTRUCTIONS FOR MAINTENANCE
6 SAFETY RELATED INFORMATION ON
TAKING OUT OF OPERATION AND REMOVAL
7
LIABILITY AND EXCLUSION OF LIABILITY
8
DECLARATION OF INSTALLATION CONFORMITY
PURSUANT TO ANNEX II 1 B
9 TECHNICAL DATA
10 BROKEN VIEW DRAWING
11 SPARE PARTS LIST
12 RELUBRICATION
UNIT
These operating and assembly instructions must be accessi-
ble to the operating personnel at all times. Please read these
operating and assembly instructions carefully before install-
ing and starting up the blower.
Subject to change. Please consult the manufacturer in case
of doubt. This document is protected by copyright. It must not
be made accessible to third parties without our express writ-
ten consent. Any form of reproduction, collection or storage
of it in its electronic form is prohibited.
1 MACHINE SPECIFICATIONS
You can fi nd our address on the cover sheet.
Please refer to the declaration of incorporation according to
Appendix II 1 B for the scope of application of the operating
and assembly instructions.
Nameplate
Only the data on the rating plate is relevant for the connec-
tion, maintenance and ordering of spare parts. The serial
number of the device and its year of manufacture can be
found on the rating plate.
1.1 Designated use
The blowers are designed for delivering clean air only.
Use of the blowers for
• aggressive,
• abrasive,
• sticky,
• toxic,
• explosive or
• very wet
media is not permitted.
The maximum temperature of the medium to be conveyed
must not exceed -20°C to +80°C with the standard model.
The maximum ambient temperature must not 40°C
or drop below -20°C.
Any solid matter or impurities in the medium to be conveyed
must be fi ltered out before they enter the blower.
We recommend a condensed water borehole at the lowest
point in the housing in the event of formation of condensa-
tion.
The blower is not suitable for installation outdoors.
Rubber pads are installed between the motor and motor con-
sole with blowers HRD 60 FU-135 and HRD 2 FU-130.
Rubber pads are installed below the base plate with blower
HRD 7 FU-120. These are supplied with the blower and must
always be used.
The rubber pads on both models must not be subjected to
any shear forces or tension.
The blower/compressor is fundamentally designed for S1 op-
eration (continuous operation).
However, a maximum of 30 switching operations per hour
are permitted.
This model of blower is not designed for installing or convey-
ing in an explosive atmosphere.
Alterations and modifi cations to the blower are not permitted.
It is not permitted to dismantle the impeller without consulting
Elektror!
Elektror blowers are characterised by a high level of opera-
tional reliability. As the blowers are very powerful machines,
the following safety instructions should be strictly observed
to avoid personal injury as well as damage to property and
the machine itself.
1.2 Mechanical hazards
Mechanical hazards on Elektror blowers are minimised ac-
cordingly using state-of-the-art engineering and by adhering
to the requirements of the occupational safety and health
protection law. We recommend using and wearing appropri-
ate protective equipment in all phases of the device’s service
life (please note the following information) in order to exclude
residual handling risks.
1.3 Danger from Reaching in and Unexpected Start-up
There is a high risk of injury from the rotating parts on the
inside of the device during operation. Decommission the de-
vice in all cases and wait until all moving parts have stopped
before opening, reaching in or inserting tools into the device.
Secure the device reliably against it being accidentally re-
started during the entire period.
Also make sure that no other dangerous situations can arise
when restarting after standing still, e.g., as a result of a pow-
er failure or blockages.
1.4 Weight and stability
There are hazards resulting from slipping or falling over dur-
ing transportation and installation. See 2.1 – Transport and
Handling as well as 3.1 – Assembly, Installation.