10
Typ Nr.
kW cos kW cos
Hz min
-1
min
-1
Hz
Mot. EN 60034-1 IP W-Kl.F
V V
A A
D-73760 Ostfildern
Germany
EN
Operating and assembly instructions ND
www.elektror.com
016303 03.14/09
CONTENT
1 MACHINE
SPECIFICATIONS
2 INFORMATION ON TRANSPORTATION,
HANDLING AND STORAGE OF THE MACHINE
3 INFORMATION ON COMMISSIONING THE MACHINE
4 INSTRUCTIONS FOR OPERATION AND USE
5 INSTRUCTIONS FOR MAINTENANCE
6
SAFETY RELATED INFORMATION ON
TAKING OUT OF OPERATION AND REMOVAL
7
LIABILITY AND EXCLUSION OF LIABILITY
8 DECLARATION OF INSTALLATION CONFORMITY
PURSUANT TO ANNEX II 1 B
9 BROKEN VIEW DRAWING
10 GENERAL SPARE PARTS LIST
11 TECHNICAL SPECIFICATIONS
12 INDICATIONS ACCORDING TO ERP IMPLEMENTING
REGULATION
327/2011
These Operating and Assembly Instructions should be avail-
able to operating personnel at all times. Read these Operat-
ing and Assembly Instructions carefully before installing and
putting the blower into service.
Subject to change without prior notice. If in any doubt, the
manufacturer should be consulted. This document is protect-
ed by copyright. It must not be disclosed to third parties with-
out our express written consent. Any form of duplication or
recording and storage in electronic equipment is forbidden.
1 MACHINE SPECIFICATIONS
Please refer to the cover sheet for our address.
For details of the scope of these Operating and Assembly
Instructions, please refer to the Declaration of Installation
Conformity pursuant to Annex II 1 B.
The technical speci
fi
cations on page 18 ff. apply to the stand-
ard version. Your blower’s speci
fi
cations may differ from
these speci
fi
cations (refer to rating plate). If this is the case,
please refer to the enclosed, additionally applicable docu-
ments or your own applicable Operating and Assembly In-
structions.
Rating plate
The data on the rating plate is applicable to connection,
maintenance and ordering of spare parts. Also refer to the
rating plate for the serial number of the appliance and its year
of manufacture.
1.1 Designated use
The blowers are exclusively designed for conveying gaseous
media without solids.
Any solid matter or impurities in the medium to be conveyed
must be
fi
ltered out before they enter the blower. We recom-
mend a condensed water borehole at the lowest point in the
housing in the event of the formation of condensation.
Use of the blowers for
• aggressive,
• abrasive,
• sticky,
• toxic,
• potentially explosive or
• very moist
media is not permissible.
The maximum temperature of the conveyed medium must not
exceed -20°C to +80°C in the standard version and 180°C in
special versions
fi
tted with a thermal barrier. Solid particles
or contaminants must be removed by a
fi
lter unit before en-
tering the blower. The maximum ambient temperature must
not 60° C in the standard version.
The blower is not suitable for open-air installation or switched-
mode operation. The blower is fundamentally designed for
S1 operation (continuous operation). However, a maximum
of 30 switching operations per hour are permitted.
The standard version of the blower is not suitable for use in
explosive atmospheres.
Special versions for applications not mentioned above are
available on request. Remodelling and modi
fi
cation of the
blower are not permitted. In the case of special equipment,
the enclosed supplementary Operating and Assembly In-
structions must be observed and adhered to. The supple-
mentary instructions differ in certain respects from these Op-
erating and Assembly Instructions.
Elektror blowers offer a high level of operational reliability.
As the blowers are high-powered machines, the safety in-
structions must be strictly observed in order to avoid injuries,
damage to objects and to the machine itself.
1.2 Mechanical hazards
The mechanical hazards in Elektror blowers have been mini-
mised in accordance with the current state of the art, as well
as the requirements for safety and health protection. To elimi-
nate any further risk on the part of the operator, we recom-
mend that suitable protective gear be used and worn during
all lifecycle phases of the appliance (please refer to the in-
structions below).
1.3 Hazards arising from reaching in and unexpected
start-up
The rotating parts inside the appliance pose a high risk of
injury during operation. Before opening, reaching in or insert-
ing tools into the appliance, always shut it down and wait
until all moving parts come to a standstill. Make sure the ap-
pliance is reliably protected against restarting while work is
in progress.
Also make sure that no hazardous situation can occur as a
consequence of restarting after shutdown, e.g. as a result of
a power cut or blockage.
1.4 Weight and stability
Beware of falling hazards during transportation and installa-
tion in particular. Refer to 2.1 – Transportation and handling,
as well as 3.1 – Installation and assembly.
1.5 Suction effect
The blowers produce a powerful suction effect.
Warning!
Objects, items of clothing and also hair can be
sucked into the intake port. Risk of injury!
Do not stand near the intake opening during op-
eration. The blower must not under any circum-
stances be operated with the intake port open,
and should, therefore, be covered with a wire
guard in conformity with DIN EN ISO 13857
(danger of injury from impeller!).