13.7 Special functions
Gas test
Turn the unit OFF using main switch 9.
Press the torch key and keep it pressed.
Turn the unit ON using main switch 9.
The solenoid valve of the unit will go on and
the gas supply can be tested / adjusted. The
function is active for 30 seconds and will be
automatically stopped. Repressing the torch
key. can interrupt the gas test.
Fan test
Turn the unit ON using main switch 9.
The fan will start for function purposes.
Operation panel test
Press the mode key 60 for at least 5 sec-
onds.
All operation displays will flash for approx.
20 seconds.
13.8 Reset setting
Master reset
Attention! All personal settings
will be lost.
All welding and secondary param-
eters are reset to their factory set-
tings.
Turn the unit OFF using main switch 9.
Press the mode key 60 and keep it pressed.
Turn the unit ON using main switch 9.
All symbols and displays will light up shortly
to confirm reset.