APPENDIX A: THE DIGITONE FM SYNTHESIS
76
You can also set if the envelopes should reset or not when they are retrigged. For more information, please
Reset on
(
ARST
/
BRST
ON)
Trig
Trig
Reset on
Reset off
Trig
Trig
Reset off
(
ARST
/
BRST
OFF)
Trig
Trig
Reset on
Reset off
Trig
Trig
The
LEVEL
parameters on the SYN2 page controls the amount of modulation from the A and B opera-
tors. For more information, please see “11.4.8 LEV B” on page 41. The
LEVEL
parameter for B is macro
mapped to both operator B1 and B2 and control their modulation amount as per this graph:
B1
B2
Leve
l
Parameter value
64
43
85
0
127
A.6 HARMONICS
The default output from an operator is a sine wave, but you can use the
HARM
parameter to add upper
partials to some of the operators’ sine waves to create more harmonically rich waveforms. The
HARM
pa-
rameter is bipolar. Negative parameter values change the harmonics of operator C, while positive parameter
values change the harmonics of operators A and B1.
Harm -
Harm +
When changing harmonics, intermediate values interpolates between the current and the next harmonic.
This interpolation works much like in wavetable synthesis, sweeping between the harmonics, smoothly
transitioning from one timbre to another. For more information, please see “11.3.5 HARM” on page 40.
The harmonic series for the operators looks like this: