Page 14
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
www.elektroautomatik.de
PS 9000 T Series
1000 W
Model
PS 9040-40 T
PS 9080-40 T
PS 9200-15 T
Power regulation
Display: Resolution
See section
„1.9.5.4. Resolution of the displayed values“
Display: Accuracy
(2
≤ 0.8% P
Max
≤ 0.8% P
Max
≤ 0.8% P
Max
Efficiency
(4
~ 92%
~ 92%
~ 92%
Analog interface (optional)
(3
Set value inputs
U, I, P
Actual value output
U, I
Control signals
DC on/off, remote control on/off
Status signals
CV, OVP, OT
Galvanic isolation to the device
Max. 1500 V
DC
Sample rate of inputs & outputs
500 Hz
Insulation
Output (DC) to enclosure (PE)
DC minus: permanent max. ±400 V
DC plus: permanent max. ±400V + output voltage
Input (AC) to output (DC)
Max. 2500 V, short-term
Miscellaneous
Cooling
Temperature controlled fan (60 mm), side inlet, rear exhaust
Ambient temperature
0..50°C
Storage temperature
-20...70°C
Humidity
< 80%, not condensing
Standards
EN 61010, EN 61326
Overvoltage category
2
Protection class
1
Pollution degree
2
Operational altitude
< 2000 m
Digital interfaces
Built-in (default)
1x USB-B for communication, 1x USB-A
Built-in (optional)
1x LAN for communication
Galvanic isolation from device
Max. 1500 V
DC
Terminals
Rear side
AC input, analog interface (optional), USB-B, Ethernet (optional)
Front side
DC output, USB-A, remote sensing
Dimensions
Enclosure (WxHxD)
92 x 237 x 412 mm
Total (WxHxD)
92 x 239 x min. 461 mm
Weight
~8.5 kg
~8.5 kg
~8.5 kg
Article number
06200446
06200447
06200448
(1 Related to the nominal values, the accuracy defines the maximum deviation between an adjusted values and the true (actual) value.
(2 The display error adds to the error of the related actual value on the DC output
(3 For technical specifications of the analog interface see
„3.5.4.4 Analog interface specification“ on page 51
(4 Typical value at 100% output voltage and 100% power