PROTECTING THE HEATING ELEMENTS 

The three boiler heating elements, 1170 W each for the 2 groups models and 1840 W each for 
the 3 groups, are protected from overheating.
Such protection is obtained by means of a thermostat with manual reloading which controls 
the cutting off of power to the heating elements.
In each of following cases:
- Excessive duration of heating, 
- Exceeding of maximum allowable temperature value, 
  the heating elements are disabled and a major fault is displayed.

10

WARMING THE CUPS 

These models are equipped with cup heater trays with the capacity to contain a large 
number of cups on various levels and to keep them warm in order to guarantee an excellent 
cup of coffee.
The heat is generated by a natural flow of hot air from the inside of the machine.

11

MEASURING THE BREWING PRESSURE  

The appliance is fitted with a pressure sensor that measures the pressure delivered by the 
pump during brewing.
Through the reading of the display, this enables technician to set manually the pump 
pressure during coffee dispensing.

8

MEASURING THE WATER SUPPLY PRESSURE 

The same sensor referred to in the previous paragraph measures, when the water pump is 
stopped, the water supply pressure with which the appliance is fed. 
Value displayed on the same display.

9

USER ALERTS

The machine can display the user the following alerts:

“ WAIT: MACHINE IS HEATING UP ”
“ MACHINE READY ”
“ MACHINE IN SLEEP MODE - NIGHT CYCLE ”

the following minor alarms:

“ BREWING NOT SATISFACTORY- CHECK COFFEE TAMPING OR DOSING OR GRINDING ”
“ BUFFER BATTERY ABOUT TO GO FLAT- REPLACE PROMPTLY ”

  the following major alarms:

“ BOILER WATER LEVEL CONTROL SYSTEM FAULT -  MACHINE OFF - REPAIR ”
“ BREWING WATER TEMPERATURE CONTROL SYSTEM FAULT -  MACHINE OFF - REPAIR ” 

SOUND EMISSION

The weighted sound emission level A of these models is 80dB uncertainty 1dB.

12

13

CONTROL OF COFFEE DOSAGE

Each group head is fitted with a flow rate sensor, or a volumetric dosage device.
It measures the volume of water being fed through the group, to ensure that the final volume 
of coffee in the cup corresponds to the value programmed by the user.
At the end, the final volume of coffee in the cup, in cubic centimetres (millilitres), corresponds 
to its weight in grams, since the specific weight of the extract being almost the same of the 
water.
To achieve this result, the device control system takes account of the quantity of water neces-
sary to wet the coffee puck, quantity that does not reach the cup during the extraction, and 
adds it to the programmed quantity. 
The quantity of water necessary to wet the coffee puck is presetted at the factory, with the 
quantity of ground coffee as 6/8 grams for singles and 12/16 grams for doubles.
The dispensing capacity corresponding to these parameters is around 1 cc/second, ie 
obtained by grinding granulometry required for the Italian espresso.
When using different quantities of coffee or different grinding granulometry, kindly contact 
Technical Support. 
This system is not requiring complex and unreliable technologies such as Gravimetric 
technology, while still allowing a very high precision in determining the so-called Brew Ratio 
but with very low production times: for example, is not requiring the filterholder weighing 
before and after loading the coffee.

7

Summary of Contents for KUP

Page 1: ...INSTRUCTION MANUAL PROFESSIONAL ESPRESSO COFFEE MACHINES KUP GB...

Page 2: ...NOT HEAT UP STEAM DOES NOT COME OUT OF THE WAND WHEN THE MACHINE IS HOT WATER COMES OUT OF THE STEAM WAND WATER DOES NOT COME OUT OF THE DISPENSING GROUP WHEN THE MANUAL BUTTON IS USED ONE DISPENSING...

Page 3: ...IC PROGRAMMING 1 1 LANGUAGE SELECTION 1 2 TIME AND DATE SETTING 1 3 NIGHT CYCLE PROGRAMMING 1 4 BREWING TEMPERATURE SETTING 1 5 BREWING CRONO ENABLING 1 6 SCHEDULED MAINTAINANCE ALERTS RESET 1 7 COFFE...

Page 4: ...ns are intended for barman espresso coffee machine operator and installation maintenance technician OPERATION INSTRUCTIONS These instructions are intended for barman espresso coffee machine operator T...

Page 5: ...as unsuitable and therefore dangerous The manufacturer cannot be held liable for any damage or injury caused by improper wrong or unreasonable use This manual is an essential and integral part of the...

Page 6: ...ent in it Children should not play with the equipment The cleaning and maintenance intended to be performed by the user should not be performed by children without super vision Disconnect the applianc...

Page 7: ...INTERFACE The machine has an alphanumeric display which allows communications between the user and the same machine in a specific selected language The inputs to the machine are executed by means of...

Page 8: ...ATTERY ABOUT TO GO FLAT REPLACE PROMPTLY the following major alarms BOILER WATER LEVEL CONTROL SYSTEM FAULT MACHINE OFF REPAIR BREWING WATER TEMPERATURE CONTROL SYSTEM FAULT MACHINE OFF REPAIR SOUND E...

Page 9: ...the following Directives 2001 95 EC General safety 2004 1935 EC Materials and objects in contact with food MOCA 2006 42 EC Machinery 2011 65 EC Restrictions on use of some dangerous material ROHS 201...

Page 10: ...ics to quit the programming options scroll the menu by the button until the following signal is displayed TO QUIT PRESS ENTER TO REPEAT PRESS then press the ENTER button the machine automatically resu...

Page 11: ...g the same button when the desired dose has been dispensed This function is enabled at all times irrespective of the machine status even in the case of a major fault so as to enable washing or checks...

Page 12: ...peration suitable for programming 2 The main menu appear on the display press any of the coffee buttons marked with the sign to scroll the menu and reach the desired topic i e GROUP 1 CLEANING or GROU...

Page 13: ...EPAIR a major fault has occurred Switch off the machine and contact Technical Assistance ALARM BUFFER BATTERY ABOUT TO GO FLAT The electronic control unit is equipped with a buffer battery that ensure...

Page 14: ...ned causes are not responsible for the fault this means that there is a blockage in the drain pipes external to the machine contact a plumber Also consult chapter B INSTALLATION paragraph 3 9 11 DISPO...

Page 15: ...ste reduced but a more rational use of non renewable resources is also ensured 1 Cut the strap that keeps the box closed 2 Open the top of the box and remove the shock proof panels inside remove the a...

Page 16: ...clockwise to shorten it There are no screws or nuts to be loosened or tightened WATER CONNECTION The water is fed thanks to a connection with the drinkable water supply at a minimum pressure of 0 15 M...

Page 17: ...ey in the lock on the control panel gently press and turn it clockwise the machine automatically enters a state of partial operation suitable for programming 2 The instructions for the using the main...

Page 18: ...be zero set by entering the Reset Code known to the technician 1 1 1 2 1 3 1 4 BREWING PRESSURE ADJUSTING With a view to obtaining the best quality in the cup brewing pressure may be adjusted Recomme...

Page 19: ...COD 05761035 Edition 22 02 2018 Tipografia Crivellari 1918 ELEKTRA SRL VIA A VOLTA 18 31030 DOSSON DI CASIER TREVISO ITALY TEL 39 0422 490405 R A FAX 39 0422 490620 E mail info elektrasrl com Website...

Reviews: