Electrothermal MH6616 Instruction Book Download Page 5

 

Page 5 of 20                                                                                                M6627   Issue 7.0 

 

 

 

3. 

SAFETY INFORMATION. 

 

This product has been designed for safe operation when used as detailed in accordance with 
the Manufacture

’s instructions. 

 

NOTE:

 Failure to use this equipment in accordance with the manufacture

’s operating instruction 

may compromise your basic safety protection afforded by the equipment and may invalidate the 
warranty / guarantee. The warranty / guarantee does not cover damaged caused by faulty 
installation or misuse of the equipment. 

 

3.1.  Prevention of Fire and Electric Shock. 

 

 

To prevent a risk of fire or electric shock, 

DO NOT

 open your 

product case without authorisation. Only qualified Service 
personnel should attempt to repair this product   

 

 

 

Replace fuses only with the type as listed in section, Parts and 
Accessories and Technical Specifications. (See fuse type and 
rating) 

 

 

 

Ensure the Mains Power Supply conforms to rating found on the 
data plate located on the back of this Product. 

 

 

 

Never

 Operate this equipment with out connection to earth / 

ground. Ensure the mains supply voltage is correctly earthed / 
grounded in accordance with current area legislation.  

 

3.2.  General Safe Operating Practice. 

 

 

Always follow good laboratory practice when using this  
equipment. Give due recognition to your compa

ny’s safety and 

legislative health & safety procedures and all associated 
legislation applicable to your areas of operation. Check 
laboratory procedures for substances being heated and ensure 
all hazards (e.g. explosion, implosion or the release of toxic or 
flammable gases) that might arise have been suitably 
addressed before proceeding.  When heating certain 
substances the liberation of hazardous gases may require the 
use of a fume cupboard or other means of extraction. 

 

 

 

Do not

 position the product so that it is difficult to disconnect 

from the mains supply.  

 

 

 

Do not 

immerse unit in water or fluids.

 

 

 

 

Do not 

spill substances onto this unit. If spillage does occur, 

disconnect unit from mains supply and follow instructionas 
detailed in Section ‘Maintenance’.  

 

 

 

Do not 

cover this unit whilst in use.

 

 

 

 

It is 

not

 recommended to leave any heating apparatus 

unattended during operation. 

 

 

 

Only use Original Equipment manufacture

’s spares and 

accessories. Ref Section 10.  

 

 
 

Summary of Contents for MH6616

Page 1: ...Page 1 of 20 M6627 Issue 7 0 SLIDE DRYING BENCH MH6616 X1 X6 INSTRUCTION BOOK ...

Page 2: ... Page 20 Appendix A Decontamination certificate Page 16 The copyright of this instruction book is the property of Electrothermal This instruction book is supplied by Electrothermal on the express understanding that it is to be used solely for the purpose for which it is supplied It may not be copied used or disclosed to others in whole or part for any purpose except as authorised in writing by Ele...

Page 3: ...ounting stage Accepting up to 50 slides it has the facility for drying slides in different orientations The temperature control is provided by a built in energy regulator controlling temperature up to 100 C The case and top are painted aluminium The various options for mounting slides on the equipment are summarised in section 7 2 ...

Page 4: ...to one s self or other people The Responsible Body and the Operator should read and be familiar with this Instruction book in order preserve the protection afforded by the equipment To prevent injury or equipment damage it is the manufacturer s recommendation that all persons using this equipment are suitably trained before use 2 2 Symbols defined Caution risk of danger See note or adjacent symbol...

Page 5: ...round Ensure the mains supply voltage is correctly earthed grounded in accordance with current area legislation 3 2 General Safe Operating Practice Always follow good laboratory practice when using this equipment Give due recognition to your company s safety and legislative health safety procedures and all associated legislation applicable to your areas of operation Check laboratory procedures for...

Page 6: ...ous areas in terms of BSEN 60079 14 1997 Keep flammable low flash point substances away from the apparatus Do not operate or handle any part of this product with wet hands Do not touch the heating surface whilst in use Do not lean or stretch over equipment Keep the Mains Plug and Lead set cable away from the heating surface ...

Page 7: ...27 Issue 7 0 4 UNPACKING AND CONTENTS Please check the contents of this carton against the diagram For your future reference please record your products Serial and Model numbers Unit Serial Number Unit Model Cat Number ...

Page 8: ...ly is to be earthed grounded in accordance with current legislation 5 1 3 Ensure only the correct rated mains input fuses are fitted Where applicable ensure the correct mains cable fuse if fitted See Technical Information Section 8 of the Instruction book 5 1 4 Check the voltage on the product data label of this unit Ensure the rating conforms to your local supply 5 1 5 It is recommended this unit...

Page 9: ...Equipment Directive WEEE Please contact your distributor supplier for further information For end users outside of the EU consult applicable regulations 6 4 This product should only be dismantled for recycling by an authorised recycling company This product and accessories must be accompanied by a completed Decontamination Certificate prior to any disposal Copies of the Certificate are available f...

Page 10: ...tor 8 Temperature control regulator knob and On Off switch 9 Mains input IEC socket 10 Data plate label 7 2 Place the slides to be dried on the bench surface The slides can be arranged on the bench in a number of ways as illustrated 7 3 Connect the unit to the mains power ensuring the correct voltage is being applied The White Power on Neon will illuminate 7 4 Set the temperature control regulator...

Page 11: ...m 3 x 1 Mains Supply Power 230V AC or 115 100V AC 50 60Hz Mains Power Lead set UK 13A BS1362 3 core earthed ground 2 meters long Moulded IEC plug and Lead set supply cord H05 V V F Replace only with equivalent cable Mains Power Lead set Europe 3 core earthed ground 2 meters long Moulded IEC plug and Lead set supply cord H05 V V F Replace only with equivalent cable Mains Power Lead set USA 3 core e...

Page 12: ...ion for damage with particular attention to the mains lead and plug set Routine cleaning of the equipment should be undertaken using a clean cloth DO NOT USE SOLVENTS FOR CLEANING ANY PART OF THIS EQUIPMENT 9 2 Fuse Replacement The mains fuse holder is located at rear your product Refer to Technical Specification Fuse Rating for correct fuse type and rating Turn your product off and remove it from...

Page 13: ...n the top plate This will reduce the risk of damage to the insulation 9 3 4 Remove any wire ties now disconnect the heater leads from the amber neon 9 3 5 Connect the replacement mat 9 3 6 Replace wire ties and insulation and hinge the heater into position over the insulation 9 3 7 Place Top plate in position and refit all the fixing screws 9 3 8 The Responsible Body shall check the electrical saf...

Page 14: ...ds Before using any cleaning or decontamination method the Responsible Body should check with the manufacturer the proposed method will not damage the equipment Prior to further use the Responsible Body shall check the electrical safety of the unit Only if all safety requirements are met can the unit be used again The above procedure is intended as a guide Should spillage occur with a toxic or haz...

Page 15: ...8 Slide Support Rod Qty 4 AZ9139 AZ9139 Rubber Feet Qty 4 AZ9140 AZ9140 Neon Clear AZ9141 AZ9142 Neon Amber AZ9143 AZ9144 Handles Qty 2 AZ9145 AZ9145 Energy Regulator AZ9127 AZ9128 Control Knob AZ9133 AZ9133 Fuse AZ9039 F1 25A AZ9040 F2 5A Plug and lead set UK M6902 Plug and lead set Europe M6332 Plug and lead set USA M6288 ...

Page 16: ...estions by deleting YES NO as applicable and by providing details in section 2 below A Blood body fluids Pathological specimens YES NO Provide details if YES B Biodegradable material that could become a hazard YES NO Provide details if YES C Other biohazard YES NO Provide details if YES D Chemical or substances hazardous to health YES NO Provide details if YES E Radioactive substances State name s...

Page 17: ...d support in using this product please contact at the following address Electrothermal Electrothermal House Unit12A Purdeys Way Purdeys Industrial Estate Rochford Essex SS4 1ND Great Britain Tel 44 0 1702 303350 Fax 44 0 1702 468731 E Mail info electrothermal com ...

Page 18: ...Page 18 of 20 M6627 Issue 7 0 12 NOTES ...

Page 19: ...Page 19 of 20 M6627 Issue 7 0 ...

Page 20: ...the email address info electrothermal com Electrothermal Electrothermal House Unit12A Purdeys Way Purdeys Industrial Estate Rochford Essex SS4 1ND Great Britain Tel 44 0 1702 303350 Fax 44 0 1702 468731 Email info electrothermal com Http www electrothermal com For the America s and Canada contact Techne Incorporated 3 Terri Lane Suite 10 Burlington NJ 08016 USA Toll free 800 225 9243Tel 609 589 25...

Reviews: