Reconnect the ClearCell Cable to the CLEARLINE Control Unit.
12.
Open the seacocks and check for any leaks.
13.
Turn the seawater intake pumps ON. The seawater intake pumps must be ON and
pumping seawater at normal flow rates for CLEARLINE to operate.
14.
Turn ON the CLEARLINE System. The CLEARLINE Cleaning LED should be illuminated in
green and the display should state it is in Cleaning mode.
15.
If the CELL Indicator is still active, then one of the following conditions still persists:
•
Water salinity is below 20 parts per thousand
•
ClearCell cable or its connectors has been compromised
•
ClearCell Electrode has excessive mud or other debris
•
ClearCell Electrode is at the end of its useful life
For further troubleshooting, see Pg.9 or Pg. 20; or contact your
CLEARLINE dealer or ElectroSea.
Any air trapped in the ClearCell canister must be bled out.
Cycle the seawater intake pump and/or loosen the ClearCell canister wing nuts to
bleed out excess air then re-tighten the ClearCell canister.
DO NOT restrict seawater flow to ClearCell canister.