4
U.S. and Foreign Patents Pending
Operating Modes
Modes and Features
4
The Operating Mode displays the state of the CLEARLINE System. Modes include:
• OFF:
CLEARLINE is powered, but is in the OFF mode and not Cleaning.
• START-UP:
CLEARLINE is performing a diagnostic self-test. This mode lasts for approximately 30 seconds.
• CLEANING:
CLEARLINE is ON and Cleaning. This is the normal operating mode for the CLEARLINE System.
• FLOW ALERT:
CLEARLINE is ON and Cleaning, but the flow rate measured is less than or equal to the value set manually in the Flow Alert feature.
• CELL INDICATOR:
CLEARLINE will continuously attempt to generate chlorine and automatically resume standard operation when conditions are resolved.
Feature Overview
• Flow Rate (GPM):
Monitors the flow rate in gallons per minute (GPM) or liters per minute (LPM) of seawater at the output of the CLEARLINE System. The flow rate is
displayed for values of 4–99 GPM (15.1–374.8 LPM). CLEARLINE CL-2000-X2.0 should not be used with flow rates >75 GPM (>283.9 LPM).
• Pump Mode:
Optional feature for vessels with two seawater intake pumps that require manual alternating of the pumps on a regular schedule.
This feature automates the manual process of alternating between Pump #1 and Pump #2. When Pump #1 or Pump #2 is operating, the green Pump light will be illuminated.
• Pump Time:
Optional feature for vessels with two seawater intake pumps that are manually cyclFed. This feature sets the desired duration of time that Pump #1 or Pump
#2 operates. Alternating time periods range from 10 minutes to 72 hours.
• Flow Alert:
An alert that indicates the flow rate is at or below a threshold level for a period of time. Flow Alert is manually set by the user.
• Display Contrast, Backlight, Imperial and Metric Units:
Adjustment of LCD display contrast and backlight levels from Lo to Hi. Selection of Imperial and Metric units for
flow in GPM or LPM.
• Default Update:
Process to restore CLEARLINE to original factory default settings. Allows the user to update CLEARLINE Control Unit firmware from a USB memory drive
supplied by ElectroSea.