background image

Warranty

22

22

U.S. and Foreign Patents Pending

ELECTROSEA, LLC 

 

Things Not Covered: 

This Limited Warranty does not cover:

1. 

A failure of the Product that results from 

(a)

 improper installation of the Product, 

(b)

 a failure to follow instructions for use of the Product,  

(c)

 jamming or clogging the Product with foreign matter, 

(d)

 use of chemicals or other substances not specified by ElectroSea for use in or  

with the Product, 

(e)

 abuse, misuse, or mishandling of the Product, 

(f)

 repair or modification of the Product by someone other than ElectroSea,  

or 

(g)

 damage to the Product, however caused;

2. 

Costs of service to remove the Product for return to ElectroSea or install a repaired or replacement Product;

3. 

Damage to the Product while in transit to or from ElectroSea; or

4. 

Damage to the vessel in which the Product is installed or any of its equipment, components, systems, fittings, air conditioners, chillers, wells, 
pumps, freezers, conduits or pipework.

How to Make a Claim: 

Call ElectroSea toll free at (888) 384-888. 

You must make your claim during the Warranty Period and within 30 days 

after you first discovered the defect that is the subject of your claim.

 You will need a receipt (or similar document) that shows that you are 

the Original Purchaser and are within the Warranty Period. You will also need the Product’s serial number, the type and length of vessel on which 
the Product is used, and a reasonably complete description of the problem you are having. ElectroSea may require that you send the Product to 
ElectroSea, at your cost, for examination. If your claim is covered by this Limited Warranty, ElectroSea will pay the cost of sending the Product  
(as repaired) or a replacement Product to you.

No Other Express Warranties: 

This Limited Warranty is the only express warranty that applies to the Product. ElectroSea has not given anyone the 

right to make any warranty or promise of any kind relating to ElectroSea or the Product, so if someone other than ElectroSea makes a warranty or 
promise relating to ElectroSea or the Product, that warranty or promise is not binding on ElectroSea. 

Limitation of Damages: 

In no event or circumstance will ElectroSea be liable to anyone for any punitive, special, incidental, indirect or 

consequential damages that relate in any way to the Product, even if ElectroSea has been advised of the possibility of those damages. 
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion may not apply to you.

Product Changes: 

ElectroSea may change the Product, the materials used in the Product, or the manner in which the Product is made from time 

to time, but will not have an obligation to incorporate any of those changes into previously manufactured Products or provide notice of any of those 
changes to purchasers of previously manufactured Products.

Summary of Contents for CLEARLINE CL-2000-X2.0

Page 1: ...888 384 8881 952 475 8084 support electrosea com www electrosea com OperationManual ModelCL 2000 X2 0 CLEARLINE System...

Page 2: ...assumed for damages resulting from the use of this product and information contained herein 1 Introduction Table of Contents 1 ElectroSea and CLEARLINE 2 Safety Considerations 2 System Features User I...

Page 3: ...arine electrochlorination system that prevents biofouling and barnacle growth in your vessel s seawater lines CLEARLINE keeps your air conditioners chillers and refrigerators operating at maximum flow...

Page 4: ...r Interface Features and Functions 1 Power on CLEARLINE The Control Unit will complete a diagnostic self test and then the green POWER light will be illuminated 2 The main status screen will be displa...

Page 5: ...CLEARLINE CL 2000 X2 0 should not be used with flow rates 75 GPM 283 9 LPM Pump Mode Optional feature for vessels with two seawater intake pumps that require manual alternating of the pumps on a regul...

Page 6: ...Flow 1 3 GPM 3 8 11 4 LPM or No Flow 0 GPM Power ON and Start up Delay Auto Mode CLEARLINE Menu Cleaning XX GPM Auto Set Backlight Contrast or Units The LCD display backlight contrast and imperial met...

Page 7: ...nd or to automate the seawater pump alternating process This optional feature is useful for vessels that have two seawater intake pumps that require scheduled manual cycling The Pump Mode and Time fea...

Page 8: ...minutes to 72 hours The CLEARLINE System is controlling the ON OFF pump operation Yes Pump 1 and Pump 2 Monitors Two seawater intake pumps are wired to the CLEARLINE System Pump 1 and Pump 2 can be mo...

Page 9: ...ow Alert occurs 1 Check vessel s strainers and intake grates for blockage 2 Check seawater pump operation 3 Check ClearCell Internal Screen see Pg 10 15 Pump Mode Cell Pump Time Default Flow Alert Upd...

Page 10: ...run off Low salinity is the most frequent cause of CLEARLINE CELL Indicator CLEARLINE will not display CLEANING or generate chlorine while vessel is operating in freshwater RESOLUTION Vessel returns t...

Page 11: ...eases seawater flow Before accessing the ClearCell Electrode double check the list of Alerts and Indicators on Pg 8 and 9 because the ClearCell infrequently requires rinsing NOTICE Low Salinity is the...

Page 12: ...eacock valves in the seawater circuit at or below the waterline This includes any output seacocks to prevent back siphoning Failure to turn OFF ALL seacock valves in the seawater circuit could result...

Page 13: ...4 Remove the pressure ring by turning the wing nuts counterclockwise 5 Remove the pressure ring 4 5 6 6 Remove the Electrode Assembly by lifting it straight up by the sides of the black plastic top D...

Page 14: ...r debris in the internal screen DO NOT TOUCH THE SURFACE BETWEEN THE ELECTRODE PLATES OR USE ANY TYPE OF MECHANICAL BRUSH THE CLEARCELL ELECTRODE PLATES CONTAIN A SPECIAL METAL OXIDE COATING THAT WILL...

Page 15: ...nd the ClearCell canister key and insert it into the ClearCell canister 9 Add the pressure ring and begin tightening down the wing nuts evenly Bleed all air out of the ClearCell canister and then fini...

Page 16: ...he CELL Indicator is still active then one of the following conditions still persists Water salinity is below 20 parts per thousand ClearCell cable or its connectors has been compromised ClearCell Ele...

Page 17: ...firmware version c Press and hold the Up Down keys simultaneously for 10 seconds then release the keys once the update begins d During the update the Control Unit is in a locked mode and cannot be use...

Page 18: ...venting unwanted marine growth barnacles and biofilm in the seawater lines If there are any concerns during the regular inspection noted above then perform a more thorough process Visually inspect all...

Page 19: ...24VDC 7 Amp Max Peak Current Normal Operating Flow 35 75 GPM 132 5 283 9 LPM Maximum Pressure 70 psi CLEARCELL Size 10 2 inches 26cm height 8 4 inches 21 3cm diameter width CLEARLINE CONTROL UNIT Siz...

Page 20: ...ical parameters and environmental temperature This is a normal operating mode See Pg 5 for Auto Mode Min Flow The flow rate is 1 3 GPM 3 8 11 4 LPM and is too low to chlorinate seawater The Min Flow i...

Page 21: ...when conditions are resolved Water Salinity Vessels often encounter brackish or freshwater when cruising inland and from storm run off Low salinity is the most frequent cause of CLEARLINE CELL Indicat...

Page 22: ...al end user purchaser of a Product directly from ElectroSea or an authorized ElectroSea Dealer a Direct Purchaser or 2 The original end user purchaser of a new vessel in which a new Product was instal...

Page 23: ...ber the type and length of vessel on which the Product is used and a reasonably complete description of the problem you are having ElectroSea may require that you send the Product to ElectroSea at you...

Page 24: ...888 384 8881 952 475 8084 support electrosea com www electrosea com 750072 002 REV A...

Reviews: