26
After exiting the programming, the door must carry out a complete opening and closing
operation in self-hold.
The force monitoring is a self-learning system which is effective from a opening width of 5 cm
to approx. 2 m. Slow progressive changes, e.g. reduction of the spring torsion, are
compensated automatically.
If force monitoring is released, only the "hold-to-run" door operating mode is possible and
error indication "F4.1" is displayed. Reset occurs with reaching a door final position.
Travel time monitoring (NES only)
Menu "3.3":
The set travel time is automatically compared with the time measured for movement between
the final limit positions. If the travel time is exceeded, error indication "F5.6" is displayed
Error indication "F5.6" is reset by closing the door.
Note!
The travel time is factory-set to 90 seconds
Recommended setting: Door travel time + 7 seconds