TSE-P 01.01 EB
40/56
599 34 55-61
DIAGNOSTICS CYCLE PHASES
Knob
position
Function
tested
Components
actioned
Operating
conditions
Parameters
displayed
1
Operation of the
display board
All the LEDs light in
sequence. When a
button is pressed, the
corresponding LED
lights
Always operative
Button code
2
Water fill to wash
compartment
- door interlock
- wash solenoid
Door closed, water fill to anti-
overflow level for max. 10 min
Water level in
mm
3
Water fill to pre-wash
compartment
- door interlock
- pre-wash solenoid
Door closed, water fill to anti-
overflow level for max. 10 min
Water level in
mm
4
Water fill to
conditioner
compartment
- door interlock
- pre-wash solenoid
- wash solenoid
Door closed, water fill to anti-
overflow level for max. 10 min
Water level in
mm
5
Hot water fill or fill to
bleach compartment
(certain models only)
- door interlock
- hot water or bleach
solenoid
Door closed, water fill to anti-
overflow level for max. 10 min
Water level in
mm
6
Heating (and, in
Jetsystem models,
recirculation)
- door interlock
- (wash solenoid if
level is lower than the
antiboiling device)
- recirculation pump
(Jetsystem models)
- heating element
Door closed, water fill to above
anti-boiling level if not yet
reached, heating for max. 10
min or to 90°C
Water
temperature in
°C
7
Check for leaks from
tub
- door interlock
- (wash solenoid if
level is <150mm)
- motor
Door closed, water fill above
150mm level if not yet
reached, motor until the drum
reaches 250 rpm
Motor speed
(rpm)
8
Drain and spin,
check for pressure
switch congruency
- door interlock
- drain pump
- motor
Door closed, water drain,
motor movement, until
maximum spin speed is
reached
Motor speed
(rpm ÷ 10)
9
Drying
(washer/dryers only)
- door interlock
- drain pump
- drying heater (full
power)
- fan motor
- condensation
solenoid
Door closed, water drain to a
level lower than the anti-boiling
device, drying heater for max.
10 min or until the drying
temperature sensor (fitted to
the duct) detects a
temperature of 150°C
NTC drying
temperature
and condenser
temperature
(°C, displayed
alternately for
2 sec)
If an alarm condition occurs during the course of the diagnostics cycle, the appliance stops and the
display or LEDs flash to indicate the alarm code.