![Electrolux WD001326 Service Manual Download Page 23](http://html.mh-extra.com/html/electrolux/wd001326/wd001326_service-manual_2385520023.webp)
TSE-P 01.01 EB
23/56
599 34 55-61
Load balanced after few attempts:
A
: low speed
B
: FUCS phase 1
C
: normal spin
Load balanced after second phase:
A
: low speed
B
: FUCS phase 1 with pulse at 470 rpm
C
: low speed
D
: FUCS phase 2
E
: normal spin
Load balanced after second phase and anti-foam
control function:
A
: low speed
B
: FUCS phase 1 with pulse at 470 rpm
C
: low speed
D
: FUCS phase 2
E
: spin with anti-foam function
F
: low speed
G
: FUCS phase 3
H
: normal spin
Load slightly unbalanced after third phase:
A
: low speed
B
: FUCS phase 1 with pulse at 470 rpm
C
: low speed
D
: FUCS phase 2
E
: FUCS phase 3
F
: reduced-speed spin
Load unbalanced after third phase:
A
: low speed
B
: FUCS phase 1 with pulse at 470 rpm
C
: low speed
D
: FUCS phase 2
E
: FUCS phase 3
F
: the spin phase is skipped and the appliance
passes to the subsequent phase