This appliance complies with the following EU directives
•
93/68/EWG CE designation directive
•
73/23/EWG dated 19.02.1973 (low voltage directive)
•
89/336/EWG dated 03./05.1989 (EMC directive including modificati-
on directive 92/31/EWG)
Safety instructions for the installer
•
The laws, ordinances, directives and standards in force in the country
of use are to be followed (safety regulations, proper recycling in ac-
cordance with the regulations, etc.).
•
This appliance corresponds to the type EN 60 335-2-6 with respect to
protection against fire. Only units of this kind may be fitted one-si-
ded to adjoining high-level cabinets or walls.
•
When fitted in combustible material, the local fire-protection regula-
tions must be observed without fail.
•
Limit to room width 550 mm, height 127 mm from lower side of grill
plate, depth 560 mm from rear with a working surface depth of
600 mm. Combustible walls and ceilings must be provided with a fla-
me-retardant lining above the grill plate in conformity with the offi-
cial fire regulations for the relevant area.
•
Protection against contact must be ensured by the installation.
Electrical connection
•
Electrical connection must be made by a certified installer.
•
The mains connection to the built-in switchbox must be made with
the existing connecting cable and corresponding to the connection
diagram.
•
A device must be provided in the electrical installation which allows
the appliance to be disconnected from the mains at all poles with a
contact opening width of at least 3 mm. Suitable isolation devices in-
clude line protecting cut-outs, fuses (screw type fuses are to be re-
moved from the holder), earth leakage trips and contactors.
•
Warning!
While being serviced the appliance must be disconnected
from the power supply. The rating plate is fitted on the underside of
the built-in switchbox.