66
E 24 - Condensate container is full
Error description
Every time a program is started the pump will run for approx. 15 seconds in order to
empty the container. Afterwards the pump will run every 5 minutes.
This error is displayed if the pump has tried to empty the container whitout the level
sensor having detected a level drop in the container.
Error analysis
Troubleshooting
Go to step 2.
The pump is working
but the drain might
be partly blocked .
NO
YES
1. Turn the
machine on and
off. Is water
coming out of
the hose?
3. Check in
the service
menu that the
correct TYPE OF
HEATING has
been selected
(MENU 5-1-2).
NO
YES
2. Is the pump
running after
the machine has
been turned on
and off?
NO
YES
The drain is blocked!
Go to step 3
Select the correct
type of heating.
Go to step 4.
4. Does the
small 24
V circuit
board relay
(487027951)
switch on after
the machine has
been turned on
and off.
NO
YES
Check wire and
Selecta Control.
Change it.
Summary of Contents for T4130
Page 1: ...Service manual Compass Control Tumble dryers T4130 T4190 487 05 40 81 EN 08 36 ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 12: ......
Page 39: ...39 Program unit CONFIG 3 Manufacturer use only ...
Page 40: ......
Page 48: ...48 E 07 Option Not in use Troubleshooting ...
Page 50: ...50 E 09 Option Not in use Troubleshooting ...
Page 61: ...61 E 19 Option Not in use Troubleshooting ...
Page 65: ...65 E 23 Option Not in use Troubleshooting ...
Page 67: ......
Page 68: ...www electrolux com laundrysystems Share more of our thinking at www electrolux com ...