63
E 21 - CMIS, polling error (warning)
Error description
This error is displayed if the dryer is connected in a CMIS system and the PC does not
communicate with the dryer (no polling) within 10 sec (time out factory setting). The error
is displayed the 10 first times the dryer is started and after this it will not reappear.
Note!
This is a warning and the dryer will operate even though the error has been
activated.
Error analysis
Start the CMIS
program on the PC
which is connected
to the ELS Network.
Go to step 2.
NO
YES
1. Has CMIS
been started on
the PC?
3. Has the ELS
Network been
set up correctly
reg. Baud rate,
addresses and
time out. An
address cannot
be used twice.
NO
YES
2. Has the ELS
Network been
connected
correctly.
NO
YES
Go to step 3.
Mount the ELS
Network cables
correctly.
Make an error
diagnosis in the
CMIS system.
Adjust menus 5-6-1,
5-6-2, 5-6-3.
Troubleshooting
Summary of Contents for T4130
Page 1: ...Service manual Compass Control Tumble dryers T4130 T4190 487 05 40 81 EN 08 36 ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 12: ......
Page 39: ...39 Program unit CONFIG 3 Manufacturer use only ...
Page 40: ......
Page 48: ...48 E 07 Option Not in use Troubleshooting ...
Page 50: ...50 E 09 Option Not in use Troubleshooting ...
Page 61: ...61 E 19 Option Not in use Troubleshooting ...
Page 65: ...65 E 23 Option Not in use Troubleshooting ...
Page 67: ......
Page 68: ...www electrolux com laundrysystems Share more of our thinking at www electrolux com ...